UK ELECTRICAL CONNECTION - ELECTRICAL REQUIREMENTS
Any permanent electrical installation must comply with the lastet I.E.E Regulations and local
Electricity Board regulations. For your own safety this should be undertaken by a qualified elec-
trician e.g. your local Electricity Board, or a contactor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC).
FUSE
ON
FUSE
FUSE
ON
ON
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage
on the rating inside the cooker hood.
This appliance is fitted with a 2 core mains cable and must be permanently connected to the
BLUE (NEUTRAL)
BROWN (LIVE)
electricity supply
via a double-pole switch having 3mm minimum contact gap on each pole. A switched Fuse
Connection Unit to BS.1363 Part 4, fitted with a 3 Amp fuse, is a recommended mains supply
connection accessory to ensure compliance with the Safety Requirements applicable to fixed
L
wiring instructions.
L supply
N
DP
The wires in this mains lead are coloured in accordance with the following code :
N Supply
Green & yellow :
Blue :
Brown :
GREEN & YELLOW
(EARTH)
As the colours of the wires in the mains lead of this appliance may not correspond with the co-
loured markings identifying the terminals in your connection unit, proceed as follows :
The wire which is coloured blue must be connected to the terminal which is marked with the
letter 'N' or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the
letter 'L' or coloured red.
Earth
Neutral
Live
GB
11