ROUGH-IN REQUIREMENTS (see figure 2)
1
1. Check all items have been received.
Towel Warmer
Bracket Pack
2. Your towel warmer requires 110V GFCI protected power. This 110V receptacle should be
located no further than 18" from the electric plug-in exit location on the towel warmer (see
figure 2), and not above the electric plug-in exit location.
3. Wall studs or plywood backing is recommended in the wall at all bracket
locations. See figure 2 for bracket locations.
INSTALLATION INSTRUCTIONS (see figure 1)
2
1. Fix wall supports "A" to the wall using the screws provided and in
locations as shown on figure 2.
2. Hang and adjust the towel warmer using set screws "B" to lock stud
"C" in the wall bracket "A". Ensure the towel warmer is firmly and
safely fixed.
PLUG-IN CONNECTION
3
TURN OFF POWER SUPPLY BEFORE PROCEEDING
Do not connect the towel warmer to the power supply until all instructions have been read and installa-
tion carried out in accord with them. Your towel warmer is 144W (110V) and conforms to CSA standards
(File ref: 2422531). Please ensure the CSA label is visible.
1. Turn off power supply.
2. Plug connector in.
3. Turn on power supply.
Warning: In case of damage or failure of the towel warmer the unit should be returned to the manufacturer or their distributor. The
warranty of 2 years on the towel warmer is NOT VALID in case of improper use or installation. Product is designed for use within
Canada and the United States only.
Kontour Linear Towel Warmer
Installation Guide
Code: K4033E / K4034E / K4035E
24" x 40" Plug-In
FIGURE 1
a
cs@icobath.com | www.icobath.com
c
b
877 757 8930

Publicité

loading

Sommaire des Matières pour ICO Kontour Serie

  • Page 1 Kontour Linear Towel Warmer Installation Guide Code: K4033E / K4034E / K4035E 24” x 40” Plug-In ROUGH-IN REQUIREMENTS (see figure 2) 1. Check all items have been received. • Towel Warmer • Bracket Pack 2. Your towel warmer requires 110V GFCI protected power. This 110V receptacle should be located no further than 18”...
  • Page 2 Kontour Linear Towel Warmer Specifications & Installation Guide Drawings Code: K4033E / K4034E / K4035E 24” x 40” Plug-In Weight Metal Model # Description Finish Watts Volts (lb) (mm) (Inches) Type Stainless K4033E Linear Electric Plug-In Chrome 144W 110V 600 x 1000 23.5 x 39.25 Steel Brushed...
  • Page 3 Guide d’installation du sèche-serviettes Kontour Linear Code: K4033E / K4034E / K4035E Console murale 24 po x 40 po REQUIS POUR L’INSTALLATION (voir la figure 2) 1. Vérifier qu’il ne manque aucune pièce. • Sèche-serviettes • Ensemble de montants de fixation 2.
  • Page 4 Guide d’installation du sèche-serviettes Spécifications et Kontour Linear Schémas Code: K4033E / K4034E / K4035E Console murale 24 po x 40 po No de Poids Type de Description Finition Watts Volts modèle (lb) (mm) (pouces) métal Éléments d’alimentation Acier K4033E Chrome 144W 110V...

Ce manuel est également adapté pour:

Kontour k4033eKontour k4034eKontour k4035e