ROUGH-IN REQUIREMENTS (see figure 2)
1
1. Check all items have been received.
•
Towel Warmer
•
Bracket Pack
2. Your towel warmer requires 110V GFCI protected power. This 110V receptacle should be
located no further than 18" from the electric plug-in exit location on the towel warmer (see
figure2),andnotabovetheelectricplug-inexitlocation.
3. Wall studs or plywood backing is recommended in the wall at all bracket
locations.Seefigure2forbracketlocations.
INSTALLATION INSTRUCTIONS (see figure 1)
2
1. Fix wall supports "A" to the wall using the screws provided and in
locationsasshownonfigure2.
2. Hang and adjust the towel warmer using set screws "B" to lock stud
"C"inthewallbracket"A".Ensurethetowelwarmerisfirmlyand
safelyfixed.
HARDWIRE CONNECTION (see figure 4)
3
TURN OFF POWER SUPPLY BEFORE PROCEEDING
Do not connect the towel warmer to the power supply until all instructions have been read and installa-
tion carried out in accord with them. Your towel warmer is 165W (110V) and conforms to CSA standards
(File ref: 2422531). Please ensure the CSA label is visible.
1. F eedtheelectricalcordlocatedatthebottomofthetowelwarmerfirstthroughtheroundtube
then through the cover plate.
2. Completeallelectricalconnectionsasshowninfigure3.
3. Push cover plate onto tube and screw to electric box with the enclosed screws. Adjust where
necessary-seefigure4.
Warning: In case of damage or failure of the towel warmer the unit should be returned to the manufacturer or their distributor.
The warranty of 2 years on the towel warmer is NOT VALID in case of improper use or installation. Product is designed for use
within Canada and the United States only.
Kontour Angle Towel Warmer
Installation Guide
24" x 39" Hardwired
FIGURE 1
FIGURE 1
a
cs@icobath.com | www.icobath.com
Code: K3023W
c
b
877 757 8930