FEATURES
Timing (cycles) and load:
Terminals: 15/0: 15V a.c. 1.2A continuous + 1A intermittent
30 sec. ON 150 sec. OFF
P = 50VA supply voltage 230V a.c. (other voltages upon
request) 50-60 Hz
PRI Protection by PTC
POWER SUPPLY INSTALLATION
The power supply must be installed in a dry place away
from direct heat or dust. Ensure easy access for inspec-
tion and maintenance. Secure the unit to the wall with the
anchor bolts provided or insert it into a rack with a omega
DIN bar. Before connecting the unit use a tester to make
sure that the cables are not broken or short-circuited. For
user safety, the equipment operates at a low voltage and is
separated from the mains by a high-insulation transformer.
We recommend installation of an overload cutout of appro-
priate capacity between the mains and the unit.
Warning: Cut off mains supply for 3 minutes to reset
the device after an overloading.
EN
INSTALLATION RULES.
Installation should be carried out observing current installa-
tion regulations for electrical systems in the Country where
the products are installed.
Ensure clearance around the appliance so there is suffi-
cient ventilation.
There must be no dripping or splashes of water on the ap-
pliance.
WARNING: To prevent injury, the appliance must be se-
cured to the wall as described in the installation instruc-
tions.
Above the power supply there must be a bipolar circuit
breaker that is easily accessible with a contact gap of at
least 3 mm.
CONFORMITY.
LV directive
EMC directive
Standards EN 60065, EN 61000-6-1, EN 61000-6-3.
INFORMATION FOR USERS UNDER DIREC-
TIVE 2002/96 (WEEE)
In order to avoid damage to the environment and
human health as well as any administrative sanc-
tions, any appliance marked with this symbol must be dis-
posed of separately from municipal waste, that is it must
be reconsigned to the dealer upon purchase of a new one.
Appliances marked with the crossed out wheelie bin sym-
bol must be collected in accordance with the instructions is-
sued by the local authorities responsible for waste disposal.
Product is according to CE mark and directives:
- EC Directives 2004/108/EC and following
norms.
- EC Directives 2006/95/EC (73/23/CEE) and fol-
lowing norms.
Power supplies constitute SELV sources in compliance
with the requirements stipulated in Article 411.1.2.2 of CEI
standard 64-8 (ed. 2003).