Always read and observe safety considerations
and installation instructions.
SAFETY CONSIDERATIONS & WARNINGS:
1. Use this unit only in the manner intended by
GAF. If you have any installation questions,
please contact Master Flow
Technical Services
®
at 1-800-211-9612.
2. For general ventilating use only. This ventilator
has an unguarded impeller. Do NOT use in
locations readily accessible to people or animals.
3. Do NOT use to exhaust hazardous material, dust,
or combustible vapors.
4. During installation, always wear appropriate
safety glasses, gloves, hard hats, restraints,
and other safety equipment to avoid injury.
Warning: Always wear durable work gloves
while handling the unit.
5. Observe all applicable building and
electrical codes.
TOOLS REQUIRED
• 3/
" or Adjustable Wrench
8
• #2 Phillips Screwdriver
• Saw (if installation requires additional
wood supports)
• Safety Eyewear
• Fall-Restraint Equipment
Figure 1a
V971382
6. Installation work and electrical wiring should be
done by a qualified person in accordance with
all building codes and the National Electrical
Code (U.S. only), including codes for fire ratings.
Contact a qualified electrician if you are not
comfortable or familiar with electrical codes
and/or installations.
7. The ventilator should be connected to a 120 volt,
60 hertz, grounded circuit only with minimum
14-gauge wiring that has at least 3 amperes of
available capacity. If you cannot confirm there is
sufficient electrical capacity on an existing circuit,
install a separate dedicated circuit. Do NOT use
an extension cord to operate.
8. Inspect for hidden utilities before cutting or
drilling. Do NOT damage electrical wiring or
other hidden utilities when cutting or drilling.
9. Make sure the fan blade is on tight and
ensure the set screw is securely tightened.
• Hard Hat and other Safety Equipment
• Utility Knife
• Work Gloves
• Ladder
• Claw Hammer
Figure 1b
Nut
Bolt
Shroud
Mounting Brackets
INSTRUCTIONS
For Gable Mount Models:
EGV5 & EGV6
10. Ducted fans must always be vented to
the outdoors.
11. Before servicing, switch power off at service panel
and lock the service-disconnect to prevent power
from being switched on accidentally.
12. FOR HOMES WITH A GAS OR OIL FURNACE
OR APPLIANCE LOCATED IN THE SAME
SPACE: The ventilator MUST be wired with a
switch or other interlocking device to prevent
the furnace and ventilator from operating at the
same time during the heating cycle. The switch
or other interlocking device MUST disconnect the
vent unit from the electrical circuit power. GAF
recommends that the switch (not included) be
installed by a qualified person in accordance
with all applicable building codes and standards.
• Pencil or Marker
• Tape Measure
• 1/2" Trade Size Cable Clamp Connector
• Type NM Electrical Cable
• Wire Nuts
Figure 2a
We protect what matters mos t
Figure 2b
™