641915-00,FSCP200 Compressor
How to Use Your Unit
How to Stop:
1.
Set the Auto/On/Off switch to "OFF".
Before Starting
Break-in Procedure
Serious damage may result if the following break-in instructions
are not closely followed.
This procedure is required before the air compressor is put into service and when the
check valve or a complete compressor pump has been replaced.
1.
Make sure the Auto/On/Off switch is in the "OFF" position.
2.
Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and
Circuit Protection paragraph in the Installation section of this manual.)
3.
Open the drain valve fully (counterclockwise) to permit air to escape and prevent
air pressure build up in the air tank during the break-in period.
4.
Set the Auto/On/Off switch to "AUTO/ON" position. The compressor will start.
5.
Run the compressor for 5 minutes. Make sure the drain valve is open and there is
minimal air pressure build-up in tank.
6.
After 5 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-
out" pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up:
1.
Set Auto/On/Off switch to "OFF".
2.
Turn regulator knob counterclockwise until it stops.
3.
Attach hose and accessories.
Too much air pressure causes a hazardous risk of bursting.
Check the manufacturer's maximum pressure rating for air tools
and accessories. The regulator outlet pressure must never exceed the maximum
pressure rating.
How to Start:
1.
Set the Auto/On/Off switch to "AUTO/ON" and allow tank pressure to build. Motor
will stop when tank pressure reaches "cut-out" pressure.
2.
Turn regulator knob clockwise until desired pressure is reached.
The compressor is ready for use.
NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or
other combustible vapors. If the compressor is being used to operate a sprayer DO
NOT place near the spray area.
All manuals and user guides at all-guides.com
3/14/06
7:31 AM
Page 12
12