FOR MODELS G0101/G0101-2#
TM
INSTALLATION INSTRUCTIONS
1. Extend your pipe 1/2" – 5/8" past the finished surface. If stand-offs are used, extend it 1 1/4" – 1 3/8".
2. Do NOT fasten the riser or elbow in the wall, as it will allow the pipe to move back and forth for ease of installation.
3. This device shall be installed in accordance with local codes or, in the absence of local codes, in accordance with the National Fuel Gas
Code ANSI Z223.1/NFPA54, or the Natural Gas & Propane Installation Code, CSA B149.1, as applicable.
2"x 4"
Pipe to protrude
Studs
1" or 1 3/8" if
STAND OFFS
are used.
Flat surface
Do NOT fasten riser
24"
Minimum
Wall sheathing
Clearance hole
Please Note: Do not install PVC Enclosure in direct Sunlight. In areas where temperatures may exceed 38° C (100° F) or less than
-29° C (-20° F) the Stainless Steel enclosure is recommended.
IMPORTANT: AVOID OVERTIGHTENING OF WALL FASTENERS TO PREVENT ENCLOSURE DAMAGE
4. Test all piping joints inside the outlet box as per B149.1 or B149.2.
5. Specifications:
G0101 Approved for Indoor or Outdoor Use
• 60,000 B.T.U. per hour Natural Gas @ 0.6 SP. @ 7" w.c.
• 90,000 B.T.U. per hour Propane Gas @ 1.53 SP. @ 11" w.c.
• As the manual valve is downstream of the gas regulator, a manual shut off valve is required upstream for servicing.
• Maximum working pressure not to exceed 0.5 P.S.I.G.
• Maximum operating range: from -28.8° C (-20° F) to 93.3° C (200° F)
6. INSTALLATION OF STAINLESS STEEL ENCLOSURE (OPTIONAL):
• If the optional stainless steel enclosure is used, sealing is required between the outlet box and the wall opening, or between the box and
the cover plate, and between the box and piping that services the outlet, as applicable, to prevent any leaking gas from entering the wall
cavity.
• A gas outlet box is required when the gas outlet is connected to the gas supply with a fitting that would otherwise be concealed, and such
fitting is not permitted in concealed locations.
• The gas outlet must be securely mounted to the building or structure. This mounting may rely on the enclosure or on the piping system if
said enclosure or piping system is sufficiently strong and secure for the purpose.
• In the event of a fire, the fusible link in the gas outlet will automatically stop the flow of gas.
G0101/G0101 2# rev 0720
3868 COMMERCIAL ST
2190-580 Nicola ave, Port coquitlam, B.c. caNada v3B 0P2 tel: (604) 877-1599 • fax: (604) 875-6776
GAS PLUG
FOR OUTDOOR USE
PVC INSTALLATION ON FLAT SURFACE
Pull out pipe.
Install valve
assembly.
BURNABY MANUFACTURING LTD.
, VANCOUVER, B.C. V5
EMAIL: info@bbymfg.com • WEB www.bbymfg.com
Seal piping.
Slide base of enclosure
over assembly and
fasten.
Push back and fasten
valve assembly to
base of box with
screws provided.
Install cover.
Test all joints for
leaks as required by
local codes.
G0101-2# Approved for Outdoor Use Only
• 60,000 B.T.U. per hour Natural Gas @ 0.6 SP. @ 7" w.c.
• 90,000 B.T.U. per hour Propane Gas @ 1.53 SP. @ 11" w.c.
N 4G2
TEL: (604) 877-1599 • FAX: (604) 875-6776
ANSI Z21.90-2019
CSA 6.24 2019
TM
PVC INSTALLATION ON SIDING
Stand-offs
Seal piping.
Siding
Install stand-offs
provided.
Secure assembly
and box as per
drawing for
installation on flat
surface.

Publicité

loading

Sommaire des Matières pour PVC GAS PLUG

  • Page 1 Clearance hole Please Note: Do not install PVC Enclosure in direct Sunlight. In areas where temperatures may exceed 38° C (100° F) or less than -29° C (-20° F) the Stainless Steel enclosure is recommended. IMPORTANT: AVOID OVERTIGHTENING OF WALL FASTENERS TO PREVENT ENCLOSURE DAMAGE 4.
  • Page 2 Espace libre Remarque importante: Ne pas installer le boîtier en PVC en un endroit où il serait exposé directement aux rayons du soleil. Dans les endroits où la température pourrait être supérieure à 38° C (100° F) ou inférieure à -29° C (-20° F), il est recommandé d’installer un boîtier en acier inoxydable.