Transport and storage
If the generator is not to be used for a
period longer than 2 months, the following
procedure must be performed before putting
it away:
Empty the fuel tank.
A
Empty the carburettor by loosening the
screw (A) and draining the petrol into a
suitable container.
Clean the outside of the generator.
Remove the spark plug, and pour a few drops
of new engine oil into the hole by the spark
plug. Replace the spark plug, but do not
replace the spark plug cover.
Pull the starter handle slowly so the engine
turns over 2-3 times. Pull the starter handle
slowly until you feel resistance.
Store in a dry, well-ventilated place.
Cleaning and maintenance
Always switch off the engine and allow the
generator to cool before undertaking any
maintenance.
Clean by wiping all surfaces with a damp
cloth.
Regularly lubricate all moving parts with
lubricating oil and check for rust formation.
Air � lter
Remove and clean the air � lter every 3
months or 50 hours of operation.
Remove the air � lter cover and take out the
� lter element.
Clean the � lter element in hot water and
mild detergent. Rinse with clean water. Press
the water out of the � lter element and allow
it to dry. Pour new engine oil onto the � lter
element, and press any excess oil from it.
Replace the � lter element, and replace the
cover.