Télécharger Imprimer la page

FALCOM Super Extract SE900 Guide D'installation, D'utilisation Et Conseils D'entretien page 3

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SECTION 5. OPERATING INSTRUCTIONS
a.
Switch power on at the fused spur.
b.
The extractor has 6 push-buttons which illuminate when selected. Their functions
are summarised in the table below.
c.
The extractor controller will automatically switch off the appliance if there has been
no operator action for 4 hours.
d.
After 30 hours accumulated running GREASE FILTER SATURATION will be sig-
nalled by all 6 indicators flashing. Reset by pressing Push-button FAN OFF (delay).
Pushbutton
LIGHTS ON/OFF
FAN ON SPEED 1 (min);
0 1
FAN OFF (immediate stop).
2
FAN ON SPEED 2
3
FAN ON SPEED 3
4
FAN ON SPEED 4 (max)
FAN OFF AFTER 10 MINUTE DELAY to clear residual
fumes; indicator flashes during time-out.
FIGURE 1
HOOD DIMENSIONS and FIXING HOLE DETAILS
Method 1
1.
Mark a horizontal line (A) in the position of the hoods bottom edge - if you have
already fitted a splashback then the top edge of this will serve.
2.
Mark a vertical centre line of the range cooker and the hood (B).
3.
Mark the positions of at least four fixing hole centres, as shown above.
4.
If using the rear exhaust spigot position, mark and knock out a hole suitable to
accommodate 150mm dia. ducting as detailed in the installation manual.
5.
Remove the grease filters to gain access the internal fixing holes and the chimney
to access the external fixing holes (if using).
6.
Secure hood using fixings suitable for the wall construction in the previously marked
positions.
Revision: 09/03/2009
Function
SECTION 6. MAINTENANCE
Regular maintenance is essential to ensure good performance and long-life.
To clean the stainless steel surfaces of the extractor use a proprietary cleaning agent.
Do not use abrasive cleaning materials or products.
Clean the grease filters in a dishwasher or by hand-washing in hot water and detergent.
Wash the filters at least every 2 months - sooner if the extractor is used extensively.
To remove a grease filter support the filter facia, remove the two retaining knobs and
then remove the filter facia with the grease filters inside. Slide the filter completely into
one facia channel and lift it out by the opposite, now visible, edge (it only comes out one
way).
To maintain the immaculate appearance of the extractor, and to minimise fire risk, en-
sure that grease deposits on the extractor surfaces are kept to a minimum by regular
cleaning.
To access the halogen lamps for replacement lever off the chrome ring immediately
surrounding the matt glass with a screwdriver. Only replace with bulbs of the same type
and rating.
SECTION 7. SPECIFICATIONS
Blower airflow, nominal:
Noise level:
Supply voltage:
Halogen lamp voltage:
Blower power input:
Halogen lamp power:
Total power:
Fuse size for electrical supply:
Blower spigot diameter:
Typical Hood weights:
SE900
23.5Kg
SE1000
25.5Kg
SE1090
26.5Kg
Method 2
1.
Remove the grease filters to gain access the internal fixing holes in the hood rear.
2.
If using the rear exhaust spigot position, mark and knock out a hole suitable to
accommodate 150mm dia. ducting as detailed in the installation manual.
3.
Offer the hood up to the wall in the desired position and mark the wall through the
fixing holes in the hood rear. This is a 2 person job.
4.
Secure hood using fixings suitable for the wall construction in the previously
marked positions.
Falcon Cooker Hoods: Super-Extract
3
1,000 m
/hr
56dBA
230V~ 50Hz
12V
1 @ 300W
2 x 20W
340W
3A
150mm
3

Publicité

loading

Ce manuel est également adapté pour:

Super extract se1000Super extract se1092