Wireless Remote Controller - Toshiba Carrier MMC-UP0181HP-UL Manuel D'installation

Climatiseur multi type unité intérieure
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

(1)
(2)
(3)
41-EN
1
In the "Field setting menu" screen, press
[ 
 ] and [ 
 ] to select "Test mode", and
then press [ 
Set/Fix]
Test mode is set, and returns to the "Field
setting menu" screen. Press the [ 
Return]
button 2 times, to open screen (2).
2
Press [ 
ON/OFF]
Operation starts, and in test mode screen (1)
opens. (While stopped, it is screen (2))
Test mode is done while the operating mode is
set to "Cool" or "Heat".
The temperature cannot be set in test mode.
Check codes are displayed in the normal way.
3
After completing test mode, in the "Field
setting menu" screen, press [ 
 ] and [ 
to select "Test mode", and then press
[ 
Set/Fix]
Screen (3) appears.
Press [ 
Set/Fix] to end test mode and do
normal operation.
– 21 –

Wireless remote controller

NOTE
Be sure to operate the unit, following the instruction
manual
Do not run the air conditioner in forced cooling mode
for a long time since it overloads the air conditioner.
Forced heating is not available for trial runs.
To perform a test run, set the unit to heating mode
with the remote controller. The unit might not operate
in heating mode, however, depending on temperature
conditions.
1
Hold down the TEMPORARY button for over
10 seconds. With a beep sound, the unit is set
to the forced cooling mode.
In approximately three minutes, it is forced to start
in cooling mode. Determine that cool air comes
out of the unit. If the unit won't start, check the
wiring.
2
Push the TEMPORARY button again (for about
one second) to stop a trial run.
The upper and lower wind direction changing
blades close, and the unit stops operation.
 ]
Checking remote transmission
1. Push the ON/OFF button on the remote controller to
determine that it works properly.
Pushing the TEMPORARY button once (for about
one second) causes the unit to enter auto operation
mode. Hold down the TEMPORARY button for over
10 seconds to begin forced cooling.
Even if you select cooling with a remote controller,
the unit does not always perform cooling operation,
depending on temperature conditions. Check the
wiring and piping of the indoor and outdoor units in
forced cooling mode.