Programming BACKWASH:
Start screen
PROG /OK + BACKWASH
The words PROG and BACKWASH blink
STOP/ECO/TURBO
Selecting speed (Eco or Turbo)
Factory values: TURBO mode for 5 minutes.
FUNCTIONING OF THE LED INFORMATION PANEL
The digital timer includes a LED information panel located in the bottom right (LED)
The LED has 3 possible states:
STATE OF LED
Lit continuously
Intermittent (1 sec.)
Intermittent (0.5 sec.)
FUNCTIONING OF THE EXTERNAL INPUT
The digital timer includes an external input that makes it possible to stop the pump when it receives an external signal.
The signal should be normally closed (NC), meaning that when the circuit is opened (no voltage between terminals),
the digital timer will stop the pump from operating.
The external input permits voltage signals, and has two possible inputs:
• 12-24 Volt (AC or DC)
• 230 Volt (AC or DC)
The connection is made by a common cable and a cable connected to 12/24V or 230 V.
STATE OF
THE INPUT
Closed, voltage in input
terminals
Open, without voltage in
input terminals
Note: In the event of not using any external input a bridging connection should be made between the power input
terminals of the digital timer and the 230 V inputs according to that indicated in the diagram. Otherwise, the
digital timer will not activate the functioning of the pump.
Electrical cabinet Dual-Speed pump
The digital timer is in operation, without any realy activated.
The digital timer is in operation, with an activated relay.
The relays are programmed to function, but the external input is activated.
STATE
OF LED
Functioning according to programming
Intermittent
TEXT text
(0,5 sec.)
activated
Selecting time (min.)
To confirm: PROG/OK
Start screen
STATE
OF SCREEN
The functioning of the pump
stops
TIME
FUNCTIONING