This device complies with Part 15 of the FCC Rules and contains licence-exempt transmitter/receivers that are
compliant with ISED (Innovation, Science and Economic Development) Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference signals, and
(2) This device must be able to tolerate interference signals. These also include interference signals that could cause
the device to function improperly.
This device complies with the nerve stimulation limits (ISED SPR-002) when operated at a minimum distance of 100
mm. Changes or modifications not expressly approved by K.A. Schmersal GmbH & Co. KG could void the user's
authority to operate the equipment.
The licence-free transmitter/receiver contained in this device satisfies the requirements of the "Radio Standards
Specification" of the Innovation, Science and Economic Development Canada (ISED) authority that apply to licence-free
radio equipment. Operation is permissible under the following two conditions:
(1) The device must not create disturbances.
(2) The device must tolerate received radio frequency interference, even if this could impair its functionality.
This device complies with the nerve stimulation limits (ISED CNR-102) when operated at a minimum distance of 100
mm.
In the event of changes or modifications that have not been expressly approved by K.A. Schmersal GmbH & Co. KG, the
user's authorisation to use the device may become ineffective.

4 Montage

4.1 Instructions de montage générales
Veuillez observer les remarques des normes ISO 12100, ISO 14119 et ISO 14120.
2
Ensure the safety sensor and actuator is mounted on a flat surface. The component can be mounted in any position.
The universal mounting holes provide for a variable mounting by means of M4 screws. Mounting: a screw length of 25
mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended
when the actuator is mounted upright and/or when the sealing discs are used. (Tightening torque 2,2...2,5 Nm). The
labelled surfaces of the safety sensor and the actuator have to be opposite. The safety sensor must only be used within
the assured switching distances ≤ sao and ≥ sar.
Afin d'éviter des interférences inhérentes au système ainsi qu'une réduction des distances de commutation, veuillez
observer les consignes suivantes:
La présence d'objets métalliques à proximité du capteur peut modifier la distance de commutation.
Tenez des copeaux métalliques à l'écart.
Distance minimale de 100 mm entre deux capteurs de sécurité ou par rapport à d'autres systèmes avec une
fréquence identique (125 kHz)
L'actionneur doit être fixé sur le protecteur de manière indémontable (vis indémontables, collage, perçage des têtes de vis,
2
goupillage) et est à protéger contre le décalage.