IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions con-
cerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do not install in
areas subject to combustible vapors or gases. Before wiring to power supply and
circuit breaker. All installation servicing or relamping must be performed by qualified service personnel. Product must
be grounded to avoid potential electric shock or other potential hazard. Product must be mounted in locations and
at heights and in a manner consistent with its intended use, and in compliance with the National Electrical Code
and local codes. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause
an unsafe condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items
such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may cause an
unsafe condition.
WARNING- This product contains chemicals known to the State of California to cause cancer, birth defects and/or
other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this
product.
INSTALLATION INSTRUCTIONS
D4LED AND D6LED SERIES
1. Bend brackets as shown in FIG. 1. Install the fix-
ture in the ceiling using mounting channels or bar
hangers (B6, B24, or by others) placed in the
adjustable mounting brackets. Mount the fixture
in the ceiling so that the weight of the fixture is
supported by the mounting channel or
bar and/or hanger wires secured to the building
structure (not ceiling).
2. Adjust the fixture so the bottom edge of the plas-
ter flange opening is flush with the finished ceil-
ing line and in alignment with adjacent fixtures.
Secure mounting brackets by tightening wing nuts
on either side of the fixture.
3. Remove J-Box cover. Remove appropriate knock-
out and install appropriate UL listed conduit con-
nector for the supply wire used. Connect white
fixture wire to white (common) supply wire, con-
nect fixture ground wire to green (ground) wire,
connect black fixture wire to black (line) supply
wire using UL listed wire connectors. Reinstall
J-Box cover.
WARNING: DO NOT pinch wires
between J-Box/ballast cover and J-Box.
Consult a Qualified Electrician for all
other options that require other wiring
configurations.
4. After all ceiling installation and finishing work
is complete, attach the safety cable to the light
engine/reflector assembly, by unscrewing the
wing nut (FIG. 2).
5. Connect the wires coming from the light engine
to the wires coming from the driver conduit by
snapping the two connectors together (FIG. 3
FIG. 4)
6. Install driver conduit connector into 7/8" hole in
light engine reflector on splice box. Caution: Do
not pinch wires
7. Insert the light engine/reflector assembly into
the opening of the housing. Pay attention to the
hexagonal rod that needs to slide into the heat
sink hole. Tighten the captive tamper proof screw
using the insert bit provided. Make sure the
reflector is flush against the ceiling.
NOTE: During step 7 use gloves to pre-
LED Light Engine/
vent fingerprints on the reflector and
Reflector Assembly
trim.
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND PROPER
OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.
KEEP THESE INSTALLATION INSTRUCTIONS
701 Millennium Boulevard • Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright 2015, 6/8/15 revision, All Rights Reserved - Printed in U.S.A.
Bend Brackets in
Bend Brackets
in Line with
Line with Marks
Marks on
on Flange
Flange.
J-Box
Cover Plate
Hexagonal Rod
Safety Cable
LED Light Engine/
Reflector Assembly
Hexagonal Rod
Safety Cable
FIG 3
D6LED Series
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93006637
during servicing or relamping, turn off power at fuse or
NOTE: B26 and B24 Bar Hanger must
be ordered separately.
FIG. 1
FIG. 1
FIG. 1
Reflector
Screw
J-Box
Cover Plate
Driver Conduit
Connector
Driver Connector
Light Engine
Connector
Hexagonal
Driver Conduit
Connector
Rod
FIG. 3
FIG 3
Driver Connector
D6LED Series
D6LED Series
Light Engine
Connector
Safety Cable
LED Light Engine/
Reflector Assembly
Page 1 of 2
NOTE: Adjustable mounting
brackets are supplied flat. To
ensure proper alignment, bend
brackets in line with marks on
flange as shown in FIG. 1.
Wing Nut
Safety Cable
Hex Nut
FIG. 2
FIG. 2
J-Box
Cover Plate
Hexagonal
Rod
Safety Cable
LED Light Engine/
Driver Conduit
Reflector Assembly
Connector
FIG 4
D4LED Series
Driver Connector
Light Engine
Connector
FIG. 4
FIG 4
D4LED Series
D4LED Series
Wing Nut
J-Box
Cover Plate
Driver Conduit
Connector
Driver Connector
Light Engine
Connector

Publicité

loading

Sommaire des Matières pour Hubbell Prescolite D4LED Serie

  • Page 1 Part No......93006637 Page 1 of 2 IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions con- cerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping.
  • Page 2 pièce ......93006637 Page 2 of 2 IMPORTANTES INFORMATIONS SUR LA SÉCURITÉ. LISEZ ET RESPECTEZ TOUTES LES CONSIGNES DE SÉCURITÉ. Lisez les informations et suivez les consignes sur l'étiquette relativement aux emplacements mouillés ou humides, à...

Ce manuel est également adapté pour:

Prescolite d6led serie