04. ELECTRICAL CONNECTION

brown
motor
cable
blue
yellow/green
04.1 Warnings
This motor has been designed to work with a stable power source
circuits for lighting Always connect the motor to the grounding system (yellow/green)
device with a voltage category III, i.e. the distance between the contacts must be of 3,5 mm at least
with maintained position
Command buttons are connected to the main voltage, so they must be properly insulated and protected
04.2 Power supply
Connect as shown in the diagram. It is mandatory to connect the YELLOW-GREEN wire to the earthing system. The electrical specifications of the motor are shown in the label applied
to the motor tube.
04.3 Command buttons
The control button must be applied to the BLACK and BROWN wires and must close on the phase. You must use "hold-to-run" button, do not use deviators with maintained position.
More than one command button can be connected via a parallel connection. The command buttons are subjected to mains voltage and must therefore be suitably insulated and
protected.
04.4 Connection of several motors in parallel
Once the limit switches of each individual motor have been programmed, the motors can be connected directly in parallel (in this way the control of the single motor is lost). If the single
command and the general command are required, a suitable centralization device must be installed upstream of each motor, for example the X51 module or the X60 EGO module. The
use of different centralization devices and not approved by the motor manufacturer implies immediate forfeiture of the motor warranty. For further information and limitations on the use
of centralization devices, contact a specialized installer.
POWER SUPPLY
POWER SUPPLY
Command
buttons
black
L (phase)
N (neutral)
Make connections with power supply disconnected Check that the power supply does not depend from electrical
GENERAL
command
L
N
blue
C
X51
L N
L
N
To avoid water infiltration, place the power cord so that it
makes a curve downwards.
POWER
SUPPLY
The supply line must be equipped with a circuit breaker. The supply line must be fitted with a
You must use buttons with spring return ("hold-to-run" type), do not use buttons
blue
SINGLE
command
blue
P
L N
02
The section of the connecting cables must be
blue
SINGLE
command
C
P
X51
GENERAL
command
OK