VANNE D'ENTRÉE ET DE SORTIE FLECK® 125
Instructions d'installation
COMPOSANTES
B
A) Vanne d' e ntrée et de sortie
Pentair® Fleck 125
B) Vannede Dérivation
C) Connecteur
CONDITIONS D'OPÉRATION ET SPÉCIFICATIONS
A
Spécification Description
Pression minimale
Pression maximale
BR42887
Température minimale de l' e au
Température maximale de l' e au
Température ambiante minimale
Température ambiante maximale
Débit
Circulation
descendante
Continu
(Chute de pression
54.9 GPM
différentielle [psid]
[12.5 m
de 15 lb/po²)
Débit de pointe
70.9 GPM
(Chute de psid de
[16.1 m
25 lb/po²)
Coefficient Cv
(débit à chute de
1 lb/po2)
4
B
A
A
20 PSI
BR42887
125 PSI
4
34°F (1°C)
110°F (43°C)
34°F (1°C)
125°F (52°C)
62134-01
Circulation
ascendante
47.4 GPM
/hr]
[10.8 m
/hr]
3
3
61.2 GPM
/hr]
[13.9 m
/hr]
3
3
14.2
12.2
3
4
B
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMEN
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
B
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
4
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
3
62134-02
Circulation
Circulation
descendante
ascendante
62.3 GPM
62.6 GPM
[14.2 m
/hr]
[14.2 m
/hr]
3
3
A
80.4 GPM
80.7 GPM
[18.3 m
/hr]
[18.3 m
/hr]
3
3
16.1
16.2
BR42887
4
2
3
PCO
ZONE
REV.
B
C
4
A
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTI
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
THIRD ANGLE
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
PROJECTION
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
VUE DU HAUT
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
APPROVALS
DATE
ALL FINISHED MACHINED SURFACES 125
TOLERANCES:
BR42887
4
TITLE
ANGLES :
1
DRAWN
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
3
APPROVED
OR BETTER.
SIZE
CHECKED
SCALE
2
3
1
2
REVISIONS
DESCRIPTION
ZONE
PCO
REV.
3
THIRD ANGLE
PROJECTION
DATE
APPROVALS
Pentair R
DRAWN
Filtratio
APPROVED
OR BETTER.
3
CHECKED
2
B
DWG NO.
S
1:2
1