Generator Shut Down; Starting Hot Engines; Low Oil Level Shutdown System; Parallel Operation - Craftsman CMXGIAC3000 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fig. K
B

Generator Shut Down

CAUTION: Equipment and property damage.
Disconnect electrical loads prior to starting or
stopping unit. Failure to do so could result in
equipment and property damage. (000136)
1. Shut off all loads and unplug electrical loads from
generator panel outlets.
2. Let engine run at no-load for several minutes to sta-
bilize internal temperatures of engine and genera-
tor.
3. Rotate Start Dial to OFF
4. Turn fuel cap OFF.

Starting Hot Engines

CAUTION: Equipment and property damage.
Disconnect electrical loads prior to starting or
stopping unit. Failure to do so could result in
equipment and property damage. (000136)
1. Turn Start Dial from STOP to RUN. This will open the
fuel valve and permit starting. See
2. Firmly grasp recoil handle and pull slowly until
increased resistance is felt. Pull rapidly up and away.

Low Oil Level Shutdown System

The engine is equipped with a low oil level sensor that
shuts down the engine automatically when the oil level
drops below a specified level to prevent engine damage
. The engine will not run until the oil has been filled
B
to the proper level. See
If the engine shuts down and there is sufficient fuel,
check engine oil level.

Parallel Operation

For output power up to 4600 running Watts, two invert-
ers can operate in parallel using Parallel Kit (optional).
See the Parallel Kit Operator's Manual or contact Cus-
tomer Service at 1-888-331-4569.
NOTE: All connections to the parallel kit should be made
while both inverters are turned off and all loads discon-
nected.
1. Make sure the Eco Mode Switch is in the same posi-
tion on both generators.
2. Make appropriate parallel connections to the out-
lets on each inverter as outlined in the owner's
manual supplied with the kit.
A
. See
Fig.
J.
3
Fig.
J.
Fig.
K.
NOTE: Do not disconnect any parallel kit connections once
the units are running.
3. Start both units per starting instructions. Once the
green output indicator illuminates, devices can be
connected and turned on using the parallel kit out-
let.
4. Follow
NOTE: Only use approved parallel kit.
005483
.
Generator Shut Down
instructions.
11

Publicité

Table des Matières
loading

Table des Matières