Replacing the UVC tube:
Attention! The UVC tubes must be placed by the manufacturer or their customer
service, or by a similar qualified person, to prevent hazards.
1. Disconnect the UVC lamp from the mains power for the maintenance.
2. Screw the socket (13) from the housing of the lamp. Remove the UV-C-tube (12)
and replace the old tube with a new one.
Assemble all parts in reverse order and ensure the O-Ring is correctly inserted.
Lubricate the O-Ring with some Vaseline.
Caution! Do not touch UVC tube (12) directly with your hand; put on cotton gloves!
Old UV-C tubes shall not get broken and must not be disposed in regular garbage
bin. Contact your local waste disposal company. Do not use sharp edged tools. In
case Quartz glass cylinder or O-ring are defect, they should get replaced
immediately.
Function check of UVC lamp
Warning: Accidental operation of the device or damage to the housing can result
in the release of harmful UVC radiation. UVC radiation can damage the eyes and
skin, even in small doses. Never look directly into the UVC tubes when they are
switched on.
Check the function of the tubes through the bluish light on the ring nuts (1) or the
protective glass (2).
18