4 ENG - OPERATIONAL MOUNTING REGULATIONS

4.1 DESCRIPTION
Storage tanks are used for accumulating of excessive heat received from the heat source like, for example, a solid fuel
boiler, a heat pump, solar collectors, fireplace inserts, etc. Some tank types allow connecting more than one heat source
at a time.
NAD type storage tanks are used for accumulation of heat in heating systems. Incorporation of the storage tank into
a heating system with a boiler using solid fuel allows for optimum running of the boiler at a favourable temperature
during boiler operation. The benefit comes mainly during the optimum running period (i.e. with maximum effectiveness)
when the excess heat that has not been taken off is accumulated in the tank.
Tanks and also possible pipe exchangers are manufactured from steel with no treatment of the internal surface,
the outer surface has a protective coating. Tanks are equipped with removable 80 mm insulation - NEODUL LB PP. Tanks
are manufactured with volumes of 500, 750 and 1000 litres. Individual versions are also equipped with one or two
2
1.4 m
pipe exchangers including inspection apertures with an inside diameter of 182 mm with the possibility
for installation of in-built TPK electric heating units.
The vessels are not intended for storage of HUW - hot utility water.
4.2 BASIC DIMENSIONS
Volume [l]
Diameter [mm]
500
750
1000
4.3 DESCRIPTION OF INDIVIDUAL VERSIONS
NAD v1
Storage tanks can be provided with one to three flanges. The flange with screw gauge 210 mm can be used for mounting
built-in TPK flange electric heating units. The flange is blocked off in the standard version. The G 6/4" extension pipe
cab be used for mounting of the TJ G 6/4" electric heating unit. Supplied with insulation with a thickness of 80 mm.
NAD v2
Storage tank can be provided with G 6/4" extension pipe. The G 6/4" extension pipe cab be used for mounting
of the TJ G 6/4" electric heating unit. Supplied with insulation with a thickness of 80 mm.
NAD v3
Storage tank with a flange with screw gauge 210 mm and extension pipes or only with extension pipes. The flange
with a screw gauge of 210 mm can be used for mounting built-in TPK flange heating units. The flange is blocked off
in the standard version. Supplied with insulation with a thickness of 80 mm.
NAD v4
Storage tank with a flange with screw gauge 210 mm for mounting built-in TPK flange heating units and one 1.4 m
exchanger for further heating system connection (e.g. SOLAR). The flange is blocked off in the standard version. Supplied
with insulation with a thickness of 80 mm.
Height [mm]
600
max. 1974
750
2022
850
2035
2