Operation Instruction - VESUVIO VESIN08N Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

C.Wiring
1) Connect to appropriate power supply, the voltage should comply with the
rated voltage of the products.
2) Earth the machine well.
3) Wiring must be handled by a professional technician according to the
circuit diagram.
4) Set leakage protector according to the local code for wiring (leakage
operating current ≤ 30mA).
5) The layout of power cable and signal cable should be orderly and not
affecting each other.
D.Switch on after finishing all wiring construction and re-checking.
VI. Operation instruction
Picture for keys
Symbol
Designation
Power ON/OFF
Press to power on or off the heat pump
Mode
Press to select Smart/Silence mode
Heat/Cool/Auto
Press to shift among cooling, heating and auto
Up/ Down
Press to set desired water temperature
Operation
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vesin10nVesin13nVesin17nVesin21n

Table des Matières