NAT Conversion Kit Instructions for D3 / 300 Series
Gas Self Clean and Dual Fuel Range
W A R N I N G
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow ALL instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
The pressure regulator and the burner orifices are set for LP gas.
To use natural gas, the regulator and burner orifices must be
converted.
To convert the range to NAT gas, follow these instructions:
1. Disconnect all electrical power at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1. Locate the pressure regulator which can be found on the back
of the range on the right hand side if facing the back of the
range.
2. Unscrew the hex nut cap from the top of the regulator.
3. Unsnap the plastic plunger from the hex nut.
4. Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note: Plunger is marked "Nat" and "LP". Converted fuel type will
be shown on the lower portion of the plunger.
Apply sideways
finger pressu re
to remove pin
from cap
NAT
D3
Burner
Left front (dual)
High
Natural
Low
Left rear
Center
NAT
Right front
Right rear
LP
LP
Bake
Broil
300 Series
Burner
LP
Left front
Left rear
Center
Right front
Right rear
Bake
Broil
Converting the Surface Burners
1. Remove the top grates, burner caps, and burner heads.
Burner
grate
Burner
cap
Burner
head
Burner
base
2. Using a 9/32" or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note: Save these orifices for future conversion back to NAT gas, if
required.
3. Locate the proper NAT surface
burner orifices included with
the kit according to the chart
below.
4. Install the orifices in their
correct location. To prevent leakage, make sure the orifice
spuds are securely screwed into the burner base.
BTU Rate Orifice Size
2.17
18,000
0.71
1,400
8,000
1.32
9,000
1.40
17,000
1.98
12,000
1.61
#38 (2.58)
30,000
#50 (1.87)
15,000
BTU Rate Orifice Size
1.98
18,000
8,000
1.32
9,000
1.40
17,000
1.98
12,000
1.61
#38 (2.58)
30,000
#50 (1.87)
15,000
Orifice
spud
Orifice
size
Orifice
1.32
1.40
1.61
2.17
1.98
0.71
1.32
1.40
1.61
1.98
1.98

Publicité

loading

Sommaire des Matières pour Viking Range D3 Serie

  • Page 1 NAT Conversion Kit Instructions for D3 / 300 Series Gas Self Clean and Dual Fuel Range Converting the Surface Burners W A R N I N G 1. Remove the top grates, burner caps, and burner heads. The conversion must be performed by a qualified Burner installer or gas supplier in accordance with the grate...
  • Page 2 5. Reinstall the converted broiler burner by first firmly attaching the igniter wire. 6. Reposition the broiler burner in its original position. 7. Replace the four screws into the broiler baffle. VIKING RANGE, LLC F21303 EN (020113) 111 Front Street • Greenwood, Mississippi...
  • Page 3 Instructions de l’ensemble de conversion au Naturel pour les cuisinières au gaz autonettoyantes et à brûleurs mixtes D3 et série 300 Conversion des brûleurs de surface AVERTISSEMENT 1. Enlevez les grilles supérieures, les chapeaux de brûleur et les têtes de brûleur. La conversion doit être confiée à...
  • Page 4 à gaz PL du brûleur et remplacez-le par le capot de brûleur de gril Naturel #50 (1,87). 5. Remontez le brûleur de gril converti en attachant fermement le câble de l’allumeur dans un premier temps. VIKING RANGE, LLC F21302 FR (080113) 111 Front Street • Greenwood, Mississippi...

Ce manuel est également adapté pour: