Tested to: UL 1482/ULC S627
Report NO: 632-000500
PREVENT HOUSE FIRES. Install and use only in accordance with
manufacturer's installation and operating instructions. Contact local building or
fire officials about restrictions and installation inspection in your area.
Use 6"/152mm minimum 24 GA. black or blued steel chimney connector with a
listed factory-built chimney suitable for use with solid woods, or an approved, lined
masonry chimney. Refer to local building codes and manufacturer's instructions for
precautions required when passing a chimney or connector through a combustible
wall or ceiling.
ANOTHER APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION (in./mm)
A. Connector to Backwall
B. Connector to Sidewall
C. Connector to Adjacent Wall
D. Unit to Backwall
E. Unit to Sidewall
F. Corner to Adjacent Wall
For additional clearances, please refer to owner's manual.
COMBUSTIBLE FLOOR REQUIRES use of a minimum 3/8"/9.5mm non-combustible floor
protector extending a minimum of 18"/406mm to the front and 8"/203mm to each side of the fuel
loading and/or ash drawer, and 2"/51mm to either side of the chimney connector.
ALCOVE INSTALLATIONS: Minimum ceiling height 64"/1626mm, minimum width 59"/1499mm,
maximum depth 30"/762mm. Listed double wall chimney connector required. Requires use of Side
Heat Shield Part No. 8301AA and Rear Heat Shield No. 8302AA.
MOBILE HOME INSTALLATIONS: Roof exit required.
ROOM. The structural integrity of the mobile home must be maintained.
Outside Air Kit No. Z8300AA - Side Heat Shield No. Z8301AA - Rear Heat Shield No. Z8310AA
One of the following listed chimney connectors (with compatible listed chimney system)
In the U.S.A : Duravent Dura Plus HT/Ameri-Tec HS/Metalbestos HT/Security 103 HT
In Canada:
listed double wall pipe.
Replace glass only with ceramic glass available from your Blaze King Dealer.
Operate with doors closed only.
Electrical rating: 115 V, 0.58 Amps, 60 Hz. Route power cord away from appliance.
Risk of electrical shock. Disconnect power before servicing.
For use with solid wood fuel only. Do not use grate or elevate fire. Build fire directly on hearth.
Manufactured by:
Design and specifications subject to change without notice. Covered by one or more of the
following U.S. Patents
D249890, D250541, D263993, D270087, 4261324. In Canada, patents 45026 and 45247.
Other U.S. and Canadian patents pending.
OM-RGT F v1.03
LISTED SOLID FUEL ROOM HEATER
Royal Guardian,
Blaze King,
Instructions d'installation et d'opération
MODEL: RGT 3001
(1/90)
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING
CONVENTIONAL-
USING SINGLE
WALL CONNECTOR
BACK WALL
D
A
B
STOVE
E
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION
Canadian stoves require high temperature pipe meeting S629M requirements and
Blaze King Industries
400 W. Whitman Dr.
College Place, WA.
99362
DO NOT REMOVE OR COVER THIS LABEL
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standard
1999
2000
2001
APR
MAY
JUN
Modèle RGT-3001
Also suitable for use in MOBILE HOME
WH-
16"/406mm
25.5"/648mm
21.5"/546mm
10"/254mm
16"/406mm
12"/305mm
ADJACENT WALL
F
C
F
DO NOT INSTALL IN A SLEEPING
Valley Comfort Systems
1290 Commercial Way
Penticton, B.C.
USA
V2A 3H5
DATE OF MANUFACTURE
2002
2003
2004
JUL
AUG
SEPT
Page 35
P/N 0194BB
REDUCED CLEARANCE
USING DOUBLE
WALL CONNECTOR
12"/305mm
21.5"/546mm
17.5"/445mm
6"/152mm
12"/305mm
8"/204mm
FLOOR PROTECTOR
4"
4"
STOVE
18"
FRONT
JAN
FEB
MAR
OCT
NOV
DEC
Date Printed: Monday, February 18, 2013