Technical data:
Conformity:
EN 50270:2015/AC 2016 (Electromagnetic Compatibility)2014/35/EU (low
voltage directive)
EN 50194 -2 : 2006 + A1:2016 + 2017 - 05 (Combustible gas detectors
directive)
2011/65/UE– 2015/863/UE: (RoHS compliant)
98/34/CE : (CE marking)
Voltage 12 VDC - 24 VDC
Connection cable red = +; Connection cable black = -
Current consumption in standby mode 100mA
Current consumption in alarm 180mA
Current consumption in extra sensor 95mA
Signal: 80dB
Sensitivity
Alarm and optional Broad Spectrum sensor
•
Propane / butane (LPG / LPG) -KO (Knock out) / anesthetic: about
95 PPM
•
Carbon monoxide (CO): about 176 PPM
Optional Specific CO sensor
•
Carbon monoxide (CO) with specific external probe: about 90 PPM
up to 40ppm after a few hours activity
The sensors can reach a temperature of 60 degrees. This is normal
TEST THE DEVICE REGULARLY!
The device generates an acoustic alarm in the presence of gas, making it
more safe to stay in recreational vehicles, It is recommended to regularly
test its correct operation.
The manufacturer is not liable in any way for failure due to an electronic
fault or incorrect installation.