TROUBLESHOOTING
PROBLEM
SMELL OF GAS
Leak detected at cylinder,
regulator or other connection.
Flames Beneath Control Panel
(Flashback Fire)
Flickering Burner Flame
or
Low Temperatures on HIGH
Setting
Burner Not Lighting
Igniter Not Working
Decreasing Heat, "Popping
Sound"
Hot spots on Cooking Surface
Regulator Humming Noise
Yellow Flame
If troubleshooting fails to solve any of these or any other issues, please contact your dealer or approved service center.
56
POSSIBLE CAUSE
SHUT OFF GAS SUPPLY VALVE AT ONCE.
DO NOT USE THE APPLIANCE UNTIL LEAK IS SEALED.
1.
Regulator fitting loose.
2.
Gas leak in hose/regulator or control valves.
1.
Venturi blocked.
1.
Excess flow safety device has been activated in
connection between cylinder and barbecue.
2.
Improper air shutter adjustment
1.
Out of LP Gas/Gas Supply Valve Off.
2.
Igniter issue.
3.
Excess flow safety device has been activated.
4.
Regulator is not fully connected to the cylinder valve.
5.
A leak in the system causing the excess flow device
to activate.
6.
Venturi blocked or misaligned with valve orifice.
7.
Orifice blocked.
8.
Hose is twisted.
9.
Improper air shutter adjustment.
10.
Burner ports blocked
1.
Igniter battery is dead
2.
Igniter wire(s) not connected
3.
Electrode misaligned on burner
4.
Igniter malfunction
1.
Out of LP Gas.
2.
Venturi blocked.
1.
Venturi blocked
2.
Burner ports partially blocked by debris
3.
Improper air shutter adjustment
1. Cylinder valve opened too quickly.
1.
Some yellow flame is normal. If it is excessive, the
venturi may be blocked.
2.
Burner ports partially blocked by debris.

CORRECTIVE ACTION

Tighten fitting and "Leak Test." (page 5)
1.
2.
See authorized service center.
1. Remove burner and clean venturi. See "Venturi Tubes"
(page 7) for assistance.
1.
Turn LP cylinder valve off then turn all burners to
OFF position. Disconnect the regulator from the
cylinder. Wait two minutes. Re-attach regulator to the
cylinder. Open the cylinder valve slowly. Wait one
minute. Light smoker oven as per "Lighting" (page 6)
2.
Adjust air shutter.
1.
Refill LP Gas Cylinder/turn on main gas supply valve.
It is an igniter issue. See "Igniter Not Working" below
2.
3.
Follow "Flickering Flame or Low Temperatures on HIGH
setting" solution above.
4.
Tighten the regulator hand wheel.
5.
Leak test connections to determine loose fitting. Tighten
fitting. Leak test system.
6.
Clean venturi See page 5 for assistance.
7.
Clean orifice with a pin or fine wire. Do not drill orifices.
8.
Straighten hose.
9.
Adjust air shutter.
10.
Remove burner & clean with soft bristle brush (e.g.
toothbrush).
1.
Replace battery
2.
Ensure main burner and side burner electrode wires are
all connected
3.
Realign electrode and clear any surrounding debris from
area
4.
Contact dealer for replacement igniter.
5.
1.
Refill LP Gas Cylinder.
2.
Remove burner and clean venturi. See "Venturi Tubes"
(page 7) for assistance.
1.
Remove burner, clean venturi. See "Venturi Tubes" (page
7) for assistance.
2.
Remove burner & clean with soft bristle brush (e.g.
toothbrush).
3.
Adjust air shutter.
1. Open cylinder valve slowly.
Clean venturi. See "Venturi Tubes" (page
1.
7) for assistance.
2.
Remove burner & clean with soft bristle brush (e.g.
toothbrush).