NATURAL GAS INSTALLATIONS:
Your new gas smoker oven comes from the factory
configured for use with LP gas. The unit can be converted
LP GAS CYLINDER
QCC®-1 QUICK CLOSING COUPLING
1.
All models are designed to be used with an LP gas
cylinder equipped with the QCC®-1 Quick Closing
Coupling system.
2.
The QCC®-1 system incorporates safety features required
by the American National Standards Institute (ANSI) and
the Canadian Standards Steering Committee.
• Gas will not flow until a positive connection has been made.
• A thermal element will shut off the flow of gas between 240°
and 300° F.
• When activated, a Flow Limiting Device will limit the flow of
gas to 10 cubic feet / hour.
3.
The LP Gas Cylinder is not included with the Gas
Smoker Oven. Be sure to purchase one with the QCC®
valve. This valve is recognized by the external threads on
the inlet port of the valve. QCC® equipped cylinders are
available from your gas smoker dealer.
NOTE: Any attempt to connect the regulator, by use of
adapters or any other means, to any other valve could
result in damage, fire or injury and may negate the
important safety features in the QCC®-1 system.
SPECIFICATION
1.
All LP gas cylinders used with this appliance m u s t be
constructed and marked in
Specifications for LP Gas Cylinders of the U.S. Department
of Transportation (D.O.T.) or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes
for Transportation of Dangerous Goods; and Commission,
as applicable.
2.
The LP gas cylinder used for this appliance must not
have a capacity exceeding 20 lb. (9 kg).
•
Approximately 18" (46cm) high and 12" (31cm)
3.
All LP gas cylinders used with this appliance should be
inspected at every filling and re-qualified by a licensed
service outlet at the expiry date (10 years), in accordance
with the DOT (USA) and Canadian Transport Commission
(Canada) codes for LP Gas Cylinders.
4.
All LP gas cylinders used with this appliance must be
provided with a shutoff valve terminating in a cylinder valve
outlet No. 510, specified in the Standard for Compressed
Gas Cylinder Valve Outlet and Inlet Connection (USA)
ANSI/CGA-V-1-1977 (Canada) CSA B96.
5.
The cylinder supply system must be arranged for vapor
withdrawal.
6.
The cylinder must include a collar to protect the valve if
to natural gas by using a natural gas conversion kit (not
included with appliance). Please contact your dealer if you
would like to order a conversion kit (Part No. FTNGK).
accordance
with
the
3
the propane capacity is in excess of 2.2 lb (1.0 kg).
7.
The cylinder must be installed as per assembly
instructions.
8.
Never fill the cylinder beyond 80% full.
9.
The cylinder valve must include a safety relief device
having direct communication with the vapor space of
the cylinder.
HANDLING
1.
Government regulations prohibit shipping full LP gas
cylinders. You must take your new cylinder to a LP
gas dealer for filling.
2.
A filled LP gas cylinder is under very high pressure.
Always handle carefully and transport in the upright
position. Protect the valve from accidental damage.
3.
The LP Gas Cylinder is not included with the
appliance. Be sure to purchase one with the QCC®
valve. This valve is recognized by the external threads
on the inlet port of the valve. QCC® equipped cylinders
are available from your appliance dealer.
4.
If the cylinder is tipped after it is connected to the
regulator, shut off the gas, disconnect the regulator and
have it checked before using it again.
STORAGE
1.
Do not store a spare LP gas cylinder under or near
this appliance.
2.
Store the LP gas cylinder outdoors in a well-
ventilated place.
3.
Do not store the LP gas cylinder in direct sunlight,
near a source of heat or combustion.
4.
If you intend to store the appliance indoors,
disconnect and remove the LP gas cylinder first.
Disconnected
cylinders must have a dust cap
installed and must not be stored in a building, garage
or any enclosed area.
5.
When the LP gas cylinder is connected to the gas
appliance, the gas appliance and LP gas cylinder
must be stored outside in a well-ventilated place.
6.
Keep out of the reach of children.
OPERATION
1.
Never connect your gas smoker to an LP gas cylinder
without the pressure regulator and hose assembly
provided, and NEVER TO AN UNREGULATED LP
GAS SUPPLY.
2.
Always leak test the LP gas cylinder to regulator
connection when connecting the LP gas cylinder to
the appliance. See "Leak Testing." (page 5)
3.
Do not operate appliance if the smell of LP gas is
present. Extinguish all flame and determine source of
LP gas before proceeding. Do not ignite the appliance
until the LP gas leak has been found and sealed.
4.
Always shut off LP gas cylinder valve when the
appliance is not in use.
If the precautions listed on this page are not taken, a
fire causing death or serious injury may occur.