Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
there are no leaks.
2. If everything is working and the water normally flows
through the filter, connect the plug of the UV-C Lamp and
verify that it is on through the light indicator (fig. 1/E).
3. The filter can work 24 hours/day for the entire year
except if the temperature drops below 4°C. To avoid
damages, unplug the power and empty completely the
filter.
CONNECTING THE HOSES
The GREEN RESET filter requires three flexible tubes
which are not included. One to connect the pump with
the inlet coupling (fig. 1/A), another to flush the clean
water from the filter outlet (fig. 1/B) back to the pond.
Another to connect the drainpipe (fig. 1/C) dirty wa-
ter when sponges cleaning is done. This water can be
used as fertilizer. When installing Green Reset filter, it
is important that the flexible hoses diameters are cor-
rectly sized. This will allow the pump to obtain maxi-
mum water flow performances. Always fasten the ho-
ses to the couplings with metal clamps (not included).
CLEANING OF THE SPONGES WITH THE SELF
CLEANING SYSTEM
GREEN RESET is equipped with a self-cleaning
system, that allows to clean the sponges without
opening the filter.
Proceed as follows:
• Lift completely the handle on the top of the filter (fig.
4).
• Turn both the hand grips from the position "FILTER"
to the position "CLEAN" clockwise or anticlockwise
until the writing CLEAN corresponds to the small hole
in the handle (fig. 5).
• Remove the cap (fig. 6/A) from the debris outlet,
connect the stepped hose connector (fig. 6/B) and
a flexible tube (not compulsory). Position the tube
towards the plants/flowers you would like to fertilize.
• Turn clockwise, with strength, the flow selector handle
to the "CLEAN" position (fig 7).
• Push up and down the top handle (fig. 8) to squeeze
the sponges. Repeat this operation until clean water
come out from the filter. When cleaning is completed,
refill the pond as you like.
• To settle the filter for normal operation, lift up
completely the top handle (fig. 9/F).
• Turn both the hand grips from "CLEAN" position to
"FILTER" position (fig. 10/G).
• Lower completely the top handle (fig. 8/F).
• Turn the flow selector handle anticlockwise to the
"FILTER" position (fig. 11/F).
• Remove the stepped hose connector (fig. 6/L) from the
debris outlet and close it with the original cap (fig. 6/I).
If the filter, after cleaning operations, is still blocked,
proceed with the filter maintenance.

FILTER MAINTENANCE

Cleaning and replacement of sponges.
The maintenance of the filter has to be done only if the
self-cleaning system cannot fully clean the sponges
because they are worn out or blocked.
CAUTION: Always disconnect the filter from the power
supply before any maintenance operations.
• Do not open the V-band (fig. 1/M) before having
unplugged the pump and UV-C lamp.
• The cap of the UV-C lamp compartment can be
opened only by specialized personnel.
• Open the V-band (fig. 1/M).
• Remove the filter dome with special care to do not
damage the OR gasket. This should be washed and
preferably lubricated (only with silicon grease) before
repositioning it (Fig. 3).
• Remove the sponges and wash them under running
water.
• Remove the grille on the bottom of the filter and rinse
it out under running water (Mod. 25 - 40 only).
• Wash bio-balls only once a year so to allow the
biological filtration not to be interrupted (Mod. 25 - 40
only).
• Then reassemble the filter following the above
procedures in reverse order.
• PLEASE, OIL PERIODICALLY THE METAL RODS
WITH THE OIL INCLUDED SO TO AVOID FRICTION
OR BREAKING OF THE SAME.
Winter season - The filter must be protected from
frost. During the winter season the filter should should
be switched off, emptied of all water, removed from
the garden and stored in a dry, sheltered place. It is
recommended to leave the filter open during storage.
UV-C lamp replacement
CAUTION: The replacement of the UV-C lamp has to
be done only by specialized personnel staff.
INSTRUCTIONS FOR THE CORRECT DISCHARGE
OF THE PRODUCT ACCORDING TO EU DIRECTI-
VE 2002/96/EC
When used or broken, the product does not have to be
discharged with the other waste. It can be delivered
to the specific electric waste collection centres or to
dealers who give this service. Discharge separately an
electric tool avoid negative consequences for the en-
vironment and for the Health and allows to regenerate
the materials so to have a great saving of energy and
resources.
WARRANTY
This product is guaranteed against defects of mate-
rials and workmanship for a period of 3 years from the
date of purchase, except the UV-C lamp and the O-
rings. The warranty certificate must be filled in by the
dealer and must accompany the pump if it is returned
for reparation, along with the cash register receipt or
similar document. The warranty covers the replace-
ment of the defective parts. In case of improper use,
tampering or negligence by the buyer or user, the gua-
rantee is void and expires immediately. The guarantee
is also void in absence of the cash register receipt or
similar document. The expenses for shipping the pro-
duct to and from the factory, or the repair station, have
to be paid by the buyer.

Publicité

Table des Matières
loading

Produits Connexes pour Sicce GREEN RESET 25

Ce manuel est également adapté pour:

Green reset 40Green reset 60Green reset 100

Table des Matières