Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
POND FILTER
EN
WITH STERILYZING UV-C LAMP
Dear Client, thank you to have chosen GREEN
RESET, the new pond filter with integrated UV-C lamp.
It guarantees high cleaning performances and it is very
easy to use and to clean!
Please, read carefully and save the following
instructions to use in the best way your filter.

SAFETY INSTRUCTIONS

In order to avoid damages to persons/things we
recommend to respect the instructions hereunder
mentioned.
1) IMPORTANT: always disconnect the power plug and
any other appliances in the pond before touching the
water, before any installation or maintenance work and
even when the appliances are not in use.
2) CAUTION: The Ultraviolet rays are dangerous.
3) This product is a filter with internal UV-C sterilizer for
usage in ornamental ponds. Do not use the appliance
for any other application.
4) Never look directly and touch the UV-C Lamp
when it is on. This can harm eyes and skin. To check
the functioning of the lamp, use only the UV-C light
indicator (fig. 1/E).
5) This product is weatherproof but not submersible.
Do not immerse the product in water. If the appliance
falls into water do not attempt to recover it. Disconnect
immediately the power plug.
6) Never use the power cable to lift or move the
appliance.
7) Do not use the appliance for swimming pools or
other application where people are using water.
8) Do not use the appliance if the power cable or plug
are damaged. If the product is damaged it must be
replaced by a specialized after sales centre.
9) Keep children and disabled persons away from this
appliance.
10) Do not open the metal V-band (fig. 1/M) or lift the
filter cover when the pump is working. This may cause
a severe hazard.
11) The electrical supply must comply with electrical
data written in the label of the product.
12) If an extension lead is required, make sure it is
waterproof.
13) The filter has a maximum working pressure of 0.4
Bar.
14) Before installing the filter, check that the UV-C light
bulb has not been damaged during transport. If this
is the case return the filter to the dealer and do not
attempt to install it.
15) This product has been designed to work with water
at a temperature between +4°C and +35°C.
16) If the temperature drops below 4°C, unplug the
power and completely empty the filter. During winter it
is better to remove the filter and store it in a sheltered
place.
17) Do not position the filter in areas liable to flooding
or where it may risk to fall into water.
18) Never operate the appliance without water.
19) Never operate the appliance with liquids different
from fresh water.
20) Never connect the filter to the hydraulic system.
WORKING
PRINCIPLES
FILTER
GREEN RESET Filters have been designed to
perform three important stages of filtration, essential
OF
GREEN
RESET
to maintaining pond water clear and healthy:
1 - Mechanical self-cleaning filtration, by special
sponges which block all larger impurities or debris. When
the sponges are obstructed they can be cleaned by the
handle cleaning system without opening the filter.
2 - Biological filtration (Mod. 25 - 40 only), by special
Bio-Balls positioned on the bottom of the filter. Bio-Balls
have a special structure with a wide surface for the
deposit of Bacteria to help maintaining the water healthy.
These special Bio-Balls have to be washed rarely as
each wash removes most of the grown bacterial flora.
3 - Sterilisation by UV-C rays, granted by the special
UV-C lamp.
The water, through the tube which connects the pump
to the Inlet of the filter (fig. 1/A), is forced towards the
mechanical filtration compartment. A special header
distributes the water uniformly over the sponges to
ensure maximum efficiency over the whole surface.
Then water reaches the grille on the bottom of the filter
compartment and Bio-Balls with bacteria that eliminate
any toxic substances (Mod. 25 - 40 only). The water is
now clean and passes through the UV-C sterilizer that
inhibits algae growth. The water returns to the pond
through the outlet (fig. 1/B).
FILTER POSITIONING
The choice in positioning GREEN RESET filter is very
important.
Carefully follow these suggestions:
• The filter can be placed at ground level or partially
buried. In this case the V-band (fig. 1/M) must be kept
at least 10 cm above ground level.
• Do not cover the filter so to avoid overheating.
• Place the filter on a flat, stable base, in an adequately
ventilated area, shaded from direct sunlight.
• Locate the filter vertically at least one metre far from
the edge of the pond and make sure it cannot fall into
water. Verify that there is enough space around the filter
for the cleaning operations.
• Do not make the filter working at pressure over 0.4
bar. Locate the filter so the Inlet (fig. 1/ A) and outlet
(fig. 1/B) point in the direction of the pond to avoid
useless bends in the connecting pipes.
FIRST INSTALLATION OF GREEN RESET FILTER
• Open the V-band (fig. 1/M) and lift the filter cover.
• Remove the sponges.
• Remove the grille under the sponges (Mod. 25 - 40
only).
• Put the biological filtering material (Bioballs) inside
on the bottom of the filter paying attention to do not
obstruct the central hose (fig. 2). Reposition the grille
on the top, fixing it correctly. Then position the sponges
(Mod. 25 - 40 only).
• Verify that the O-ring in the top groove of the canister
is positioned in a proper way (fig. 3).
• Position the filter cover on the gasket and close the
filter with the V-band paying attention that the O-ring
is still positioned in a proper way. Be careful to do not
pinch your fingers or the power cable.
• Connect the inlet and outlet hoses.
• Verify that the flow switch is in the "FILTER" position
(fig. 1/G - 10).
After having done the abovementioned operations,
please proceed as follows:
1. Switch on the pump and let it work for some minutes
in order to verify that everything is functioning and

Publicité