order to ensure proper device operation.
• I f the environment in which the product is installed also houses a fuel-operating device
(water heater, methane stove etc., that is not a "sealed chamber" type), it is essential to
ensure adequate air intake, to ensure good combustion and proper equipment operation.
• I nstall the product so that the impeller is not accessible from the air outlet side as
verified by contact with the Test Finger in compliance with the current safety regulations.
• C eiling installation
In order to guarantee the IPX4 degree of protection against moisture in case of ceiling
installation, use the appropriate ceiling mount kit, which is not included. Use only the
rear entry hole for supply cables. If there is a possibility of condensation along the air
discharge duct, provide a drainage system to prevent condensation from discharging
into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit.
• R ecessed installation
In case of recessed installation in plasterboard walls, the specific fixing kit must be
used (accessory on request).
INTRODUCTION
FLOo (Fig. 1) is a centrifgual fan designed to ensure air extraction in small/medium-
sizedrooms such as bathrooms, toilets and kitchens. Suitable for air discharge through
long length ducting.
Wall or ceiling installation, surface or recessed in plasterboard walls (Fig. 2).

TECHNICAL SPECIFICATIONS

• M aterial: High quality, impact and UV-resistant ABS colour RAL 9010.
• D esign front cover removable for cleaning without the use of tools.
• R emovable filter in PP to protect the impeller and the motor from dust.
• H ighly quality forward-curved impeller for high performance and top silence.
• S ingle phase 2-speed motor with integral thermal protection.
• M otor mounted on ball bearings that guarantee a longer product life cycle (30,000h)
and suitable for cold climates.
• T he fan is double insulated: no earth connection is required.
• S uitable for continuous or intermittent operation.
• I PX4 degree of protection.
• P ower supply 220V to 240V~ 50/60Hz.
VERSIONS
STANDARD
The fan is operated using a separate ON/OFF switch or via a light switch (Fig. 49A).
WITH TIMER (over-run)
The fan is provided with a timer circuit which is adjustable from aprox. 1 minute to 25
minutes via trimmer (Fig. 50A).
Operation: connected according to the diagram in Fig. 49B, after the light is switched
Airflow
Static pressure
Code
m
/h max
3
VNDC80
104/62
VNDC80T
104/62
VNDC80HT
104/62
VNDC100
104/62
VNDC100T
104/62
VNDC100HT 104/62
Power
Pa max
W max
251/142
28/17
251/142
28/17
251/142
28/17
251/142
28/17
251/142
28/17
251/142
28/17
Sound pressure
dB(A) @3m
38/27
38/27
38/27
38/27
38/27
38/27
5