12
Positioning
This appliance can be installed in a dry,
well ventilated indoor where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Cli‐
Ambient temperature
mate
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Some functional problems
might occur for some types of
models when operating outside
of that range. The correct
operation can only be
guaranteed within the specified
temperature range. If you have
any doubts regarding where to
install the appliance, please
turn to the vendor, to our
customer service or to the
nearest Authorised Service
Centre.
The plug should be accessible
after installation.
TECHNICAL DATA
Technical data
Height
Width
Depth
Rising time
Voltage
Frequency
All manuals and user guides at all-guides.com
Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
• The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
• The manufacturer declines all
responsibility if the above safety
precautions are not observed.
• This appliance complies with the E.E.C.
Directives.
Ventilation requirements
The airflow behind the appliance must be
sufficient.
1. Put the freezer in horizontal position
on a firm surface. The cabinet must be
on all four feet.
2. Make sure that the clearance between
the appliance and rear wall is 5 cm.
3. Make sure that the clearance between
the appliance and the sides is 5 cm.
mm
mm
mm
Hours
Volts
Hz
876
946
667,5
32
230 - 240
50