Electrical Connection - Assa Abloy effeff 901-IO-20 Installation Et Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical connection

23 24 25 26 27 28
Relais 8 Relais 7
1 2 3 4
5 6
Fire alarm connection:
Input Assignment – switch to GND
1
Temporary release repeat triggering
2
Timer contact –
3
Release with delay
4
Acknowledge alarm
5
Button, left-hand –
Release with delay,
Acknowledge alarm
6
Button, right-hand –
Lock, temporary release
7
1-Contact –
Lock,
Temporary release,
Release with delay,
Acknowledge alarm
8
Burglar alarm system
The settings can be changed with the ePED Service Interface USB and the ePED Service Software (separate instructions
D01103 ePED Service Interface USB 1386–SIF and D01104 ePED Service Software 1386–Service).
29 30 31 32 33 34
35 36 37 38 39 40
Relais 6 Relais 5
Relais 4 Relais 3
7 8 9 10
11 12 13 14
No fire alarm
3
4
5
41 42 43 44 45 46
Relais 2 Relais 1
15 16 17 18
19 20 21 22
Local connection
6
3
4
Relay Assignment
1
Door closed and locked
2
Electric strike only temporary activation
3
Safety lock
4
Door drive –
Automatic operation,
Always open
5
Door drive –
Activation,
Temporary release
6
Door is closed
7
Tamper alarm
(Cover contact and key switch)
8
Collective alarm
!
Note!
Avoid connection errors: To
avoid errors and for a bet-
ter overview, ASSA ABLOY
Sicherheitstechnik recom-
mends the following as-
signment of cable col-
ours.
CAN_H
CAN_L
V
+
B
GND
Central connection
5
6
3
Colours
wh
br
gn
ye
4
5
6
+ –
V
B