P9/12
dimmiNg coNtrol /
100%
80%
60%
40%
20%
0
2
4
Power sUPPly /
Operational Voltage
tension d'alimentation
Absolute Maximum Voltage
voltage maximum absolu
Max. current consumption - strobe signal line
consommation max. – signal strobe
Max. current consumption - remote control lines
consommation max. – contrôle à distance
Max. current consumption - dimming control line
consommation max. – dimming
oPeratiNg coNditioNs /
-10° to +40°C / 80% of humidity without condensation. Not for outdoor use.
No thermal shock (maximum temperature variation: 10°C in 24h).
-10° à +40°C / 80% d'humidité sans condensation. Non adapté à une utilisation en extérieur.
Pas de choc thermique (variation de température maximum de 10°C en 24h).
coNtrôle dU dimmiNg
VOLTS
6
8
10
alimeNtatioN
coNditioNs d'UtilisatioN
• Potential dimming between 0 & 10 V.
With 0V applied to the Dimming pin, the product
is at 100% of its lighting power. With 10V applied,
it is reduced to 30% of lighting power.
• Dimming possible entre 0 et 10V.
À 0V au niveau du Dimming, le produit est à 100%
de sa puissance lumineuse. À 10V, il est réduit à
30% de la puissance d'éclairage.
24 V at the light input ( ± 10%)
24 V à l'entrée de l'éclairage ( ± 10%)
30 V at the light input
30 V à l'entrée de l'éclairage
5 mA
5 mA
2 mA