ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
Error
Diagnostic Code
NO
Code
Error Image
11
tE
12
3E
13
Hr
14
nF1
15
suds
16
AE
17
SF
18
2E
WF405ATP-03144A_EN.indd 3
WARNING
Description
Abnormal high/low temperature or
tE
resistance (Thermal sensor or PBA
resistance).
MICOM is attempting to drive the motor
but is not getting any response signals
3E
from the hall sensor. Visual check shows
motor is not running. (Locked, Defective
Hall Sensor or Overload)
This error code appears when the
Hr
heater is 96°C or above.
This error code appears when the
water temperature is 50°C or above
nF1
for 8 seconds or longer in the Wool
and Delicate course.
Suds is detected during the washing
session. ("SUdS" is not an error. If the
suds
washer is in suds period, "SUdS" will
light up instead of remaining time.)
Communication error between SUB
AE
PBA and MAIN PBA
SF
System Error
Voltage for motor control bus is
2E
over or under specified limit.
Go to " Board Input Test" and check
Water Temperature. Check loose
or pinched wires. Replace PCB or
thermistor.
Evaluate wire harness for loose or
unhooked connections. Go to "
Quick Test Mode" and test Motor.
Replace PCB
Please connect the hot/cold water
hose connection correctly.
Guide a user to reduce amount of
detergent usage.
Check Main PBA, SUB PBA & Wire-
harness. Replace PCB
Replace PCB
Replace PCB