Cold water
Min. flow pressure
(Soft water)
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
Hourly water demand (average for 60°C program) for
standard connection (with hot and cold water)
If hot water supply is not available add hot water demand to
cold water demand.
Warm
Max. temperature
water
Min. flow pressure
(Soft water)
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
Hourly water demand (average for 60°C program)
Machine can be connected to a hot water supply line with a
temperature of 70°C to max. 85°C. This requires a separate
inlet hose. This additional inlet hose is available from Miele.
The machine must also be reprogrammed by Miele Service.
If hot water is not available, connect hot water hose to cold
water valve!
Drain
Max. temperature
LP
pump
Drain hose(int. diameter)
On-site hose connector for drain hose
(int. diameter x length)
Max. transient throughput
Drain pump head height (from floor level)
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090. Drain manifolds serving several
machines must be of sufficient cross-section.
Vented
Nominal air throughput in vented mode
Max. permissible pressure loss
Waste air/gas temperature, max.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Miele adapter, Mat. no. 6595070 (int. diameter 100 mm) for
flexible aluminum ducting and adapter, Mat. no. 915051, (ext.
diameter 110 mm) for connection to standard heat-resistant
plastic pipes supplied.
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection:
=> Air intake from installation site
Min. air intake cross-section
(to prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace
the air extracted.
Fittings
4 × clamps
(supplied)
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Technical datasheet: PWT 6089 EL LP
Date: 11.2014
14.5 psi
100 kPa
145 psi
1000 kPa
2.9 gal/min
11 l/min
¾" garden hose
¾" garden hose
thread, male
thread, male
61"
1550 mm
approx. 18.5
approx. 70 l/h
gal/h
158°F
70°C
14.5 psi
100 kPa
145 psi
1000 kPa
2.9 gal/min
11 l/min
¾" garden hose
¾" garden hose
thread, male
thread, male
61"
1550 mm
approx. 18.5
approx. 70 l/h
gal/hr
158°F
70°C
7/8"
22 [DN 22] mm
7/8" x 1 3/16"
22 × 30 mm
6.9 l/min
26 l/min
39 3/8"
1000 mm
188 cfm
320 m³/h
0.06 psi
420 Pa
176°F
80°C
3 15/16"
100 mm
3 15/16"
100 mm
2
37 in
237 cm²
¼" x 2"
6 × 50 mm
5/16" x 1 9/16"
8 × 40 mm
Page: 11