MAINTENANCE
• Before performing any maintenance always disconnect propane gas tank.
• Keep the heating item free and clear from combustible materials.
• Visually inspect burner for obstructions and keep tank enclosure free and clear from debris.
• Use a soft brush to get rid of the mild stains, loose dirt and soil after the burner is completely
cooled down. Wipe down with a soft cloth.
• Harsh weather conditions may cause stubborn stains, discoloration and possibly rust pitting.
• Permanent damage may occur if powder or solvent comes in contact with painted or plastic
components on this heating unit.
• Keep the heating unit stored away from direct sunlight.
• If storing this unit inside, disconnect the propane gas tank from the gas valve.
• Not using manufacturer approved or supplied parts/accessories may result in a defective condition
and void the warranty of this heating unit.
• Carbon deposits may pose as a fire hazard; clean the reflector and inside of the glass tube with
soap and water if any carbon deposits are present.
•
Do not obstruct the flow of the combustion and ventilation air.
TROUBLESHOOTING
Problem
Pilot won't light
Pilot won't stay on
Burner won't light
Cause
Gas valve may be off
Gas tank may be empty
Orifice may be blocked
Air is within supply system
Loose connection
Debris around the pilot
Loose connection
Thermocouple is bad
Gas leak within the line
Lack of gas pressure
Gas pressure is low
Orifice may be blocked
Control knob isn't on
Thermocouple is bad
Pilot light assembly is bent or not in the
correct location
Solution
Turn the gas valve on
Refill the gas tank
Clean out the orifice
Pump out air from all lines
Check all fittings and tighten connections
as necessary
Clean out the debris
Check all fittings and tighten connections
as necessary
Call for a replacement part and replace
the thermocouple
Check all connections; call for a
replacement part if anything is damaged
Gas tank is almost empty
Gas tank is almost empty
Clean out the orifice
Turn the control knob on
Call for a replacement part and replace
the thermocouple
Place pilot light in the correct location
and retry lighting procedure
1-866-771-2663 | Page 13