3
Transport and storage
3.1
Inspection of condition on delivery
Inspect the valves for damage upon receipt.
In case of transport damage, determine and document the precise extent of the damage, and
report it immediately to the supplying dealer/carrier and the insurer.
3.2
Transportation
Transport the valves in the packaging supplied.
The valves are delivered ready to operate with body ends protected by cover caps.
Protect the valves against hammering, impacts, vibrations and dirt.
Adhere to a transport temperature range of -20 °C to +65 °C.
3.3
Storage
Store the valves in a clean and dry place.
Make use of a desiccant or heating in damp storerooms to prevent the formation of
condensation.
Adhere to a storage temperature range of -20 °C to +65 °C.
4
Description of the valves
Refer to the respective catalogue page for further detailed information.
4.1
Structure
Design
Non-automatically opening and closing gate valve.
Component
Body
Bonnet
Operating mechanism
Obturator
Stem bushing
Body end
4.2
Valving marking
The globe valves are provided with an individual marking for identification.
Symbol
DN.....
PN.....
-.....°C +.....°C
01/19
12345
01234567
EN1626
0045
e.g. 1.4571
22
Operating instructions
Design
Straight-type; angle type; diagonal type
Flanged, inside screw
Non-rising stem
Disc with seal made of non-metallic materials
Not self-sealing, packing gland, bellows
with welding end
with welded pipes
Explanation
Nominal diameter
Rated working pressure (max. permissible working
pressure)
Temperature, min. / max.
Manufacturer's mark "HEROSE"
Year of construction MM/YY
Type
Serial no.
Standard
CE-mark and number of the notified body
Material
Phone +49 4531 509-0