Télécharger Imprimer la page

growland STL-0-15-AT Instructions De Montage page 2

Publicité

PT1
JP1
(1.5-5.0 A)
JP1
(6.0-10.0 A)
D
E
STL-0-15-AT
STL-0-30-AT
STL-0-50-AT
STL-0-60-AT
STL-0100-AT
16/10/2013
According to
the low voltage
directive:
2006/95/EC /
the EMC directive:
2004/108/EC
Kickstart
Normal start
A
B
C
D
E
net weight
gross weight
83
160
66
71
108
290 g
360 g
83
160
66
71
108
350 g
410 g
83
160
81
71
108
440 g
530 g
113
178
92
102 140
675 g
765 g
113
178
92
102 140
650 g
740 g
Mounting instruc tions
EN
Speed controller for single phase voltage controllable motors.
Technical data
Voltage: 230 Vac - 50 Hz
Current range Fuse
STL-0-15-AT
0.1-1.5 A
F 3.0 A
STL-0-30-AT
0.1-3.0 A
F 5.0 A
STL-0-50-AT
0.2-5.0 A
F 8.0 A
STL-0-60-AT
0.5-6.0 A
F 10.0 A
STL-0100-AT
0.5-10.0 A
F 16.0 A
Enclosure: plastic R-ABS, UL94-V0, grey RAL 7035, IP54
Max ambient temperature: 35 °C
For indoor use only, non-condensing!
The electronic speed controllers of these series control the
speed of single phase (230 Vac - 50 Hz) voltage controllable
motors by varying the supplied voltage through phase angle
control.
There is a potentiometer and a separate ON/OFF switch with
built in telltale, the minimum speed allowed can be adjusted
internally with a little trimmer (factory preset = 100 V). The ter-
minal board has a supplementary connection to bypass the
ON/OFF switch (automatic start) or to branch off 230 V not
controlled (three wire motor connection, valve, lamp, damper,
etc ...).
There are two working modes, internally selectable by placing
or removing the red jumper on the PCB (see illustration). Kick-
start: the motor will always start (or restart) at max. speed for 8
seconds, after that the motor speed automatically follows the
position of the potentiometer. Normal start: the motor starts
according to the position of the potentiometer.
1. Be sure that the controller is in OFF position.
2. Take of the box cover by loosening the 4 screws. Note that
the potentiometer is connected to the PCB with 2 wires.
3. Connect mains, motor(s) and earth cables of the proper
diameter to the terminals according to the scheme below.
4. Start the controller and adjust the minimum speed: with the
potentiometer at minimum, adjust the little trimmer so that
the motor continues turning or restarts smoothly in case of
power faults. The minimum speed is factory preset at 100 V.
5. Close the box and verify that the installation works fine.
6. The operating position must be as shown below.
Connections (see fig.)
L N
main supply 230 Vac– 50 Hz
N
neutral
Pe
earth connection
L1 N
230 Vac not regulated output for connecting lamp,
valve, dampers ... or three wire motor connection;
branched off after switch and fuse
input: to bypass switch and fuse (ATTENTION)
N
regulated output to motor
jumper jumper removed = normal working mode
jumper in place = 'kickstart' working mode
trimmer minimum speed adjustment trimmer
Transport and stock keeping
Avoid shocks and extreme conditions, stock In original packing.
Warranty
Two years from delivery date against defects in manufactur-
ing. Any modifications or alterations to the product relieve the
manufacturer of all responsibility. The manufacturer bears no
responsibility for any misprints or mistakes in this data, and
modifications or improvements to the product can be made at
any time after date of publication.
Maintenance
In normal conditions the controllers are maintenance-free. If
soiled clean with dry or dampish cloth. In case of heavy pol-
lution clean with a non-aggressive product. In these circum-
stances the controller should be disconnected from the mains.
Pay attention that no fluids enter the controller. Only reconnect
the controller to the mains when it is completely dry.
Motor protection
It is always recommended to install a proper motor protection
device.
All works may only be carried out by skilled personnel
following the local regulations and AFTER the controller
is completely separated from the mains. Replace fuse only
with same type and rating.
Montage-instruc ties
NL
Toerenregelaar voor éénfase spanningsregelbare motoren.
Technische gegevens
Netspanning: 230 Vac - 50 Hz
Bereik
Zekering
STL-0-15-AT
0,1-1,5 A
F 3,0 A
STL-0-30-AT
0,1-3,0 A
F 5,0 A
STL-0-50-AT
0,2-5,0 A
F 8,0 A
STL-0-60-AT
0,5-6,0 A
F 10,0 A
STL-0100-AT
0,5-10,0 A
F 16,0 A
Behuizing: plastic R-ABS, UL94-V0, grijs RAL 70355, IP54
Max. omgevingstemperatuur: 35 °C
Voor gebruik binnen, niet-condenserend!
De elektronische toerenregelaars van de STL-serie regelen de
snelheid van monofasige (230 Vac/50 Hz) spanningsregelbare
motoren door middel van variatie van de toegevoerde span-
ning.
Zij worden bediend door een potentiometer en een aparte aan/
uit-schakelaar met een ingebouwd signaallampje, de minimaal
toegelaten snelheid kan intern met een trimmertje ingesteld
worden. Er is op de klemmenstrook een extra-aansluiting voor-
zien waarmee enerzijds de aan/uit-schakelaar kan overbrugd
(automatisch opstarten) worden of anderzijds een niet-geregel-
de spanning van 230 V kan afgetakt worden.
Er zijn twee modes: selecteerbaar bij de installatie door het
plaatsen/verwijderen van de jumper (zie figuur). 1. Normale
start (jumper weggenomen): de motor start volgens de positie
van de potentiometer. 2. Harde start (jumper geplaatst): de
motor zal altijd gedurende 8 seconden op zijn hoogste snelheid
opstarten. Na deze periode daalt de motorsnelheid volgens de
positie van de potentiometer.
1. Verzeker er u van dat de regelaar UIT staat.
2. Neem voorzichtig het deksel af door de 4 schroeven los
te draaien. Noteer dat de potentiometer met 2 draden met
stekker verbonden is met de PCB.
3. Sluit de netvoeding, motor(en) en aarding aan met kabels
van de gepaste diameter op de aansluitklemmen volgens
onderstaand schema.
4. Zet de regelaar aan en stel de minimum snelheid in: dit
gebeurt door met de potentiometer op minimum, het kleine
trimmertje zo in te stellen dat de motoren blijven draaien of
terug starten bij stroomonderbreking. De minimum snelheid
werd bij de productie ingesteld op 100 V.
5. Sluit de doos en controleer de goede werking.
6. Neem de werkingspositie in acht zoals onderaan wordt
getoond.
Aansluitschema (fig.)
L N
voeding 230 Vac– 50 Hz
N
neutraal
Pe
aardingsaansluitingen

Publicité