CHARGING AND USAGE OF THE LI-ION BATTERY
•
Check if the voltage characteristics of the battery charger match the voltage of the AC
outlet.
•
The lamp will operate for approximately 8+ hours before turning OFF.
•
Only charge indoors on a dry surface. See warning label on charger for more information.
CARE AND USE OF LITHIUM-ION (Li-ion) BATTERIES
•
Li-ion battery packs last longer when charged and stored in a temperature range
between 50°F to 86°F (10°C to 30°C) away from heat, sunlight and humidity.
•
Always charge batteries to full capacity before long-term storage (approximately 30 days)
to prevent aging. After storage they must be charged, which may require conditioning
(two or three charge/discharge cycles) to reach full capacity.
•
Do not subject these batteries to repeated deep discharges that run the batteries down
completely on a regular basis as this will greatly shorten battery life.
•
Li-ion batteries generally have no voltage sag until the last 10% of charge.
•
Li-ion batteries have no toxic lead or mercury, and a life expectancy of 500
charge/discharge cycles or more, provided the battery is not overcharged or heavily
discharged. Recycle according to local disposal laws.
MEASURING LAMP INTENSITY
To ensure that your uVision™ series lamp is operating at the required UV intensity, it
should be checked periodically. Spectro-UV offers a variety of sensors and meters. The
AccuPRO™ XP-2000 combines the functionality of a UV and visible light radiometer/
photometer, and is specially designed to measure UV irradiance with wavelengths of
320–400nm (with peak at 365nm) and visible light from 460–675nm (with peak at 555nm).
Other suitable meters include the AccuMAX™ XRP-3000 radiometer/photometer kit, using
dual-wavelength UV-A and VIS sensor detectors to accurately measure the irradiance of a
light source. The AccuMAX™ XR-1000 digital readout unit with the XS-365 UV sensor or the
DM-365XA digital readout unit can also be used for UV-A measurement.
For
product
information
and
230-7305.
Consult
Safety
Data
www.Spectro-UV.com.
To Charge the Lamp,
Connect the Battery
Charger to the Unit
technical
assistance,
call
us
Sheet
(SDS)
on
our
4
KEY FEATURES
•
Nominal steady state intensity of 9,000 µW/cm
(38cm).
•
Large 7-inch diameter coverage area at 15 inches (38cm) with a minimum
UV-A intensity of 1,200 µW/cm
•
Less than 1.0 foot-candle (11 lux) emission.
•
Long-lasting UV-A lenses.
•
Cool running, fanless design.
•
Lightweight and rugged construction.
•
White Light, LED Inspection Light.
•
IP65 Rated: The
and from low pressure jets of water (from all directions). For more details,
consult EN 60529 (British BS EN 60529:1992, European IEC 60509:1989).
TECHNICAL SPECIFICATIONS
uVision™ Series
UV-365ZEH
Height
Length
Width
Weight
Light Source
ELECTRICAL SPECIFICATIONS
Battery Charger:
Input:
Output: 1
at
1-866-
website
at
UV-365ZEH Technical Details
(+/- 250 µW/cm
2
.
2
Series lamps are protected from total dust ingress
uVision™
UV-A (365nm) and white light
9.5 inches
4.625 inches
3.75 inches
2.65 lb. (1,202 g)
3 UV-A LEDs, 1 white light LED
100-240V/50-60Hz, 0.4A, DC
6.8V/1.8A
5
) at 15 inches
2