Technical Data - LEGRAND Celiane 672 30 Mode D'emploi

Masquer les pouces Voir aussi pour Celiane 672 30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Céliane™
No neutral switch
672 30

Technical data

Min.
60 W
60 W
110 V
Max.
150 W
150 W
Min.
60 W
60 W
230 V
Max.
300 W
300 W
Incandescent lamp
Halogen lamp
ELV halogen lamp with ferromagnetic or
electronic transformer
Cabling
Important :
- A load must be connected before starting product
learning in a scenario.
- Ferromagnetic transformers must be charged to more
than 60% of their rated power.
- Allow for the efficiency of ferromagnetic transformers
when calculating the permissible power
(e.g. transformer for a 50-W lamp with 0.78 efficiency
=> actual power consumed by the transformer = 64 VA)
Safety instructions:
This product should be installed preferably by a qualified electrician. Incorrect installation and use can entail risk of
electric shock or fire.
Before carrying out the installation, read the instructions and take account of the product's specific mounting location.
Do not open up the device. All Legrand products must be exclusively opened and repaired by personnel trained and
approved by LEGRAND. Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement
and guarantees.
Only use genuine accessories
Radio frequency
60 VA
150 VA
60 VA
300 VA
Electronic protection:
In case of overload and above the maximum use temperature, the product
automatically regulates the power with reduced lighting.
9
N
L
10
Voltage
Frequency
2 x 1.5 mm
Depth = 40 mm min
Range
Approx. 200 m in free field
+5°C to +45°C
±
100 - 240 V
50 - 60 Hz
2
or 1 x 2.5 mm
2
868.3 MHz

Publicité

Table des Matières
loading

Table des Matières