The appliance can be controlled using a remote
control powered by a 1.5 V carbon-zinc alkaline
batteries of the standard LR03-AAA type.
• Do not place the remote control near to heat
sources.
• Used batteries must be disposed of in the proper
manner.
MaINTENaNCE
Alarm signal reset
• Switch of the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the
leds start to flash.
Cleaning the filters
• The filters are washable and must be cleaned
when led S1 flashes or at least every 2 months
of operation, or more frequently for particularly
heavy usage.
• Remove the filters one at a time, supporting
them with one hand and turning the safety
knobs (pull and turn).
• Wash the filters, taking care not to bend them.
Allow them to dry before refitting.
• Replace them and fix them using the safety
knobs provided (pull and turn).
GB
REMOTE CONTROL (OPTIONaL)
Grease filters
CLEaNING METaL GREaSE FILTERS
17