2

Wall Mounting

2-1
Locate studs
41 - 61 cm
(16 - 24 in.)
2-2
Mark the wall
2-3
Drill pilot holes
2-4
Tighten lag bolts
[24]
[23]
8
Wood stud
< 16 mm
(5/8 in.)
[01]
[01]
For assistance in determining wall plate location, see Height
Finder at sanus.com.
Verify the center of the stud(s) using an awl, a thin nail, or an
edge to edge stud finder.
CAUTION:
Avoid potential personal injuries and property
damage!
Any material covering the wall must not exceed 16 mm (5/8
Ù
in.).
Minimum wood stud size: common 2 x 4 in (nominal 1.5 x
Ù
3.5 in).
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Pilot holes MUST be drilled to a depth of 89 mm (3.5 in.), using a
5.5 mm (7/32 in.) diameter drill bit.
89 mm
(3.5 in.)
CAUTION:
Avoid potential injuries or property damage!
Improper use could reduce the holding power of the lag bolt. To
avoid potential injuries or property damage
DO NOT over-tighten the lag bolts [23].
Ù
Tighten the lag bolts [23] only until the washers [24] are
Ù
pulled firmly against the wall plate [01].
13 mm
5.5mm
(1/2 in.)
(7/32 in.)
6901-002115 <01>