ENERGY TOP B
If the room temperature is lower than the required value, it is advisable to set a higher
order curve and vice versa. Proceed by increasing or decreasing in steps of one and
check the result in the room.
90
85
80
70
60
50
40
30
20
20
10
fig. 12 - Compensation curves
OFFSET = 20
90
10
9
8
7
85
6
80
5
70
4
60
3
50
2
40
1
30
20
fig. 13 - Example of compensation parallel curve offset
If the Remote Timer Control (optional) is connected to the boiler, the above ad-
A
justments are managed according to that given in table 1.
Table. 1
Heating temperature adjustment Adjustment can be made from the Remote Timer Control menu and the boiler
control panel.
DHW temperature adjustment
Adjustment can be made from the Remote Timer Control menu and the boiler
(with optional hot water tank
control panel.
installed)
Summer/Winter Switchover
Summer mode has priority over a possible Remote Timer Control heating
demand.
Eco/Comfort selection (with
On disabling DHW from the Remote Timer Control menu, the boiler selects the
optional hot water tank installed)
Economy mode. In this condition, the button detail 7 - fig. 1 on the boiler panel
is disabled.
On enabling DHW from the Remote Timer Control menu, the boiler selects the
Comfort mode. In this condition it is possible select one of the two modes with
the button detail 7 -fig. 1.
Sliding Temperature
Both the Remote Timer Control and the boiler card manage Sliding Tempera-
ture adjustment: of the two, the Sliding Temperature of the boiler card has prior-
ity.
System water pressure adjustment
The filling pressure with the system cold must be approx. 1.0 bar. If the system pressure
falls to values below minimum, the boiler card will activate fault F37 (fig. 14). Flashing of
the arrows (details 18 and 24 - fig. 1) together with the error code indicates which boiler
shell is in fault status.
fig. 14 - Low system pressure fault
Once the system pressure is restored, the boiler will activate the 120-second
A
air venting cycle indicated on the display by FH.
3. INSTALLATION
3.1 General Instructions
THE BOILER MUST ONLY BE INSTALLED BY QUALIFIED PERSONNEL, IN COMPLI-
ANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE
PROVISIONS OF CURRENT LAW, THE NATIONAL AND LOCAL REGULATIONS,
AND THE RULES OF PROPER WORKMANSHIP.
ENERGY TOP B is a heat generator arranged to operate alone or in cascade (bank).
When two or more generators are installed in cascade with the original kits ENERGY
TOP B, respecting the prescriptionsFERROLIof this manual, they can be considered as
a single heat generator of total power equal to the sum of the powers of all the units con-
nected in cascade.
All the requirements of the current standards and regulations applicable to this "equiva-
lent" total heating capacity generator must be met. In particular, the place of installation,
safety devices and fume exhaust system must be adequate for the total heating capacity
of the bank of units.
10
9
8
7
6
5
4
3
2
1
0
-10
-20
OFFSET = 40
90
10
9
8
7
85
80
70
60
50
40
30
20
eco
reset
comfort
cod. 3541G011 - Rev. 00 - 07/2015
In fact, each ENERGY TOP B is a complete and independent heat generator, equipped
with its own safety devices. In case of overtemperature, no water or no circulation in the
unit , the protection devices cause the unit to shutdown , preventing its operation.
The installation instructions given in the following paragraphs concern single units and
connection in cascade.
Given below are the possible configurations for connection in cascade.
Configurations in line
6
5
4
3
fig. 15 - Configuration - in line (example with 4 modules)
2
1
Table. 2 - Configurations in line
Heating power
max.
kW
75
116
150
232
225
266
307
348
300
382
464
375
416
457
498
539
580
450
532
614
696
525
566
607
648
689
730
771
812
600
682
764
846
928
1003
1044
1078
1160
A
Combinations
Model
Model
Model
Model
Module 1
Module 2
Module 3
Module 4
80
/
/
125
/
/
160
/
250
/
160
80
/
160
125
/
250
80
/
250
125
/
160
160
/
250
160
/
250
250
/
160
160
80
160
160
125
250
160
80
250
160
125
250
250
80
250
250
125
160
160
160
250
160
160
250
250
160
250
250
250
160
160
160
160
160
160
250
160
160
250
160
160
250
250
160
250
250
160
250
250
250
250
250
250
160
160
160
250
160
160
250
250
160
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Model
Ø;
A
Module 5
/
/
/
500
/
/
/
500
/
/
200
1000
/
/
200
1000
/
/
200
1500
/
/
200
1500
/
/
200
1500
/
/
200
1500
/
/
200
2000
/
/
200
2000
/
/
200
2000
/
/
200
2500
/
/
200
2500
/
/
200
2500
/
/
300
2500
/
/
300
2500
/
/
300
2500
/
/
300
3000
/
/
300
3000
/
/
300
3000
/
/
300
3000
80
/
300
3500
125
/
300
3500
80
/
300
3500
125
/
300
3500
80
/
300
3500
125
/
300
3500
80
/
300
3500
125
/
300
3500
160
/
300
4000
160
/
300
4000
160
/
300
4000
160
/
300
4000
250
/
300
4000
250
80
300
4500
250
125
300
4500
250
160
300
5000
250
250
300
5000
63
EN