INSTALLATION INSTRUCTIONS - MATRIX FLOOD
MATRIX HOUSING
(2X) 5/16-18
SOCKET HD BOLT
TORQUE TO 10 FT-LBS
WIRING ACCESS COVER
POLE BRACKETS
POLE TENON
701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000
SAVE THESE INSTRUCTIONS
FIXTURE WIRING
TERMINAL BLOCK
Fixture Installation:
1.
Using a T-20 Torx bit, remove Wiring Access
Cover. Retain screws.
2.
Assure that the Pole Brackets are loose
enough for the Knuckle to slide over the pole
tenon.
3.
Attach the Knuckle to pole tenon by sliding
the Knuckle onto the pole end. Tighten each
of the (4) 5/16-18 Mounting Bolts to
approximately 21-25 ft-lbs.
4.
Route fixture wiring into the interior of the
Knuckle.
5.
Attach Matrix Housing to Knuckle by aligning
the Housing above the Knuckle and sliding it
down onto the (2) 5/16-18 Socket Head Cap
Screws. Ensure wiring is not pinched
between Housing and Knuckle.
6.
Secure Housing to Knuckle by tightening (2)
5/16-18 Socket Head Bolts using the 1/4"
Allen Wrench, to approximately 10 ft-lbs.
7.
Make proper wiring connections from the
pole supply wires and the fixture wires at the
terminal block located inside the knuckle.
8.
Using a T-20 Torx bit, re-attach Knuckle
Wiring Access Cover using the (2) 8-32
Screws that were removed in Step 1.
SEE SHEET 4 FOR ANGLE AJUSTMENTS
AND FINAL INSTRUCTIONS
HOUSING SECTION
TAKE KNUCKLE FROM
SHIPPING CARTON, POSITION
AS SHOWN. SLIDE INTO
MATING END OF HOUSING,
THEN DRIVE TWO 5/16-18
SOCKET HEAD BOLTS.
TIGHTEN TO 10 FT-LBS.
www.hubbelloutdoor.com
SHEET 3 OF 4
KNUCKLE