INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious
injury or death. Only qualified electricians should install this fixture and the installation MUST conform to the Canadian
Electrical Code Part I and all local codes and ordinances. Ensure that only proper tools, materials, and equipment are used to
complete the installation.
SAFETY
Proper grounding is required to ensure personal safety.
Fixture should be mounted in locations where unauthorized personnel will not readily subject it to tampering.
Do not use this equipment for anything other than its intended purpose.
Servicing this equipment should be performed by qualified service personnel.
Save these instructions.
MIN 90 °C SUPPLY CONDUCTOR
INSTALLATION
BOLLARD INSTALLATION
1.
Attach the anchor bolts to the concrete with a bolt centred diameter of
5.118" and the thread should protrude at least 3" from the concrete.
2.
Insert a nut followed by a washer to each anchor bolts.
3.
Place base plate over the over the bolts.
4.
Install wire and tie bracket on the base plate to one of the anchor bolts.
5.
Loosely tighten the flat washer and the nuts onto the anchor bolts.
6.
Level the base plate by adjusting the leveling nuts under the base plate.
Then tighten the upper nuts on top of the base plate.
7.
Place the conduit wires through the wire-tie in the wire-tie bracket, Do the
connection through the zip-tie and tighten the wire – tie to make sure the
wires are above the ground level.
8.
Make wiring connection as per the wiring diagram.
9.
Place the fixture above the base plate and tighten the four hex head socket
screws at the bottom of column.
ROTATING THE HEAD WITH CUTOFF SHEILD
1.
Loosen the four set screws under the head and rotate the head to desired
position.
2.
Re- tighten the screws.
WIRING
Check that the line voltage is correct.
Connect fixture GROUND (green) wire to power supply GROUND (green) wire.
Connect fixture WHITE wire to power supply NEUTRAL wire.
Connect fixture BLACK wire to power supply LINE wire.
The fixture includes 0-10V dimming functionality, connect GREY and VIOLET
wires to a 0-10V dimming controller (optional).
RAB DESIGN LIGHTING INC.
READ, UNDERSTAND
before installing the equipment.