Safety Instructions (Continued)
Warning labels
Find and read all warning labels found on the air
compressor.
Motor Specifications and Electrical Requirements
Power Supply and Motor Specifications
WARNING:
!
To reduce the risk of electrical hazards, fire
hazards or damage to the tool, use proper circuit
protection . Your tool is wired at the factory for
operation using the voltage shown . Connect tool
to a power line with the appropriate voltage and a
15-amp branch circuit . Use a 15-amp time delay
type fuse or circuit breaker . To reduce the risk
of shock or fire, if power cord is worn or cut, or
damaged in any way, have it replaced immediately .
The AC motor on this unit is a universal type, having the
following specifications.
Voltage
Amperes
Hertz
Phase
RPM
It is wired at the factory for operation on 110 - 120V AC,
60 Hz service.
5
110 - 120
13.8
60
Single
17,500