E
II 3 G Ex ic mc IIC T6 Gc
II 3 D Ex ic mc IIIC T80°C Dc
Cert. ARTIDOR 22ATEX9999
S/N: AS229999
Artidor Explosion Safety, Emopad 38, 5663 PB Geldrop
The Netherlands, +31 40 7873911, https://artidor.com
Example of an AR-030 door magnet label
7.
Installation instructions
•
Installation of explosion-safe equipment such as this product must be carried out by
personnel specially trained and qualified to do this, following the relevant requirements
of the installation standard EN 60079-14.
•
For the installation and use of this product the relevant safety regulations and also the
generally recognized latest state of the technology apply.
•
During assembly, care must be taken that the framework, screws and surface are strong
enough to take the weight and the holding force of the door magnet.
•
Isolate power from the electrical supply cable prior to installation.
•
The door magnet is double isolated and therefore an earth connection is not necessary.
•
Install the connection cable and make sure that it is protected from mechanical and
chemical influences.
•
Connect the end of the cable in a proper way to an external connection box and ensure
this is done professionally. The connection box is not supplied. Use a connection box
that it is suitably protected for the (explosion hazard) classification of the surroundings in
which it will be used.
•
The connection cable has two wires. Both of them can be connected to the positive (+)
or neutral (-) connection. The door magnet is secured against voltage reversal and can
be used with direct and alternating current.
8.
Maintenance
For the maintenance of the AR-030 door magnet the requirements as stated in EN 60079-17
apply.
Installation manual explosion-safe AR-030 door magnet
8 / 36
AR-030
24 V AC/DC, 1.5 Watt
F = 490 N
-25 °C < Ta < +50 °C
Year: 2022
IP65
12-2022