12 . Insulation class
13. Surrounding temperature
14 . Disconnecting type
15. Over current protection
nOTICE!
If the "Er" appears on the screen it means that temperature either raised over 99 °C, it
decreased below -9 °C or the sensor got damaged. To secure together the boiler and
installation up to the time of the sensor replacing pump should be continuously On till
that time.
4.3. The functions of EKOSTER 2 regulator
Use
The microprocessor temperature regulator for central heating boiler is designed to control the air
blow in wood-fired boiler and to actuate circulating pump in central heating system
The regulator performs the following functions:
• maintaining the set temperature of boiler by controlling air blow,
• smooths start-up of a blower,
• setting the blower power (service mode),
• programmable boiler „blow-through",
• automatic control switch-off after boiler burnout (extinguishes),
• blower interlocking when feeding the boiler,
• control of central heating circulating pump depending on its set operating temperature,
• „COMFORT SYSTEM",
• protection against freezing or overheating of boiler,
• signalling of temperature sensor's damage,
• regulating the brightness of display - increased during read out and change of regulator
settings,
• control panel connecting possibility,
• room thermostat cooperation,
• automatic turning off in case of wrong burning up in the boiler,
• EKOSTER CONTROL cooperation.
Regulator working description
After switching on, the regulator passes into
corresponding lamp . Operation commences after pressing
when boiler's temperature rises above operating threshold - that is, difference between set boiler
temperature and factory-set temperature difference "dt". Automatic transition into
state occurs 30 minutes after boiler temperature drops below operating threshold. CONTROL
receptacle is for connecting remote control .
Pushbuttons
and
causes display and change of set boiler temperature . Pressing and holding pressed causes
increase in speed of temperature setting change .
Pressing the
• with temperature below operating threshold: switching on or switching off control, signalled
by
or
• with temperature above operating threshold: blower interlocking signalled by pulsation of
indicator, enabling feeding of fuel into the boiler. Automatic return to operation
pressing .
serve to change the settings. During normal operation, pressing them
button causes:
indicators respectively,
I
0 – 40 °C
full
2 x 1.25 A (fuse)
state signalled by switching on of
button or automatically