Select Location
The proper location will ensure peak performance of your
appliance. We recommend a location where the unit will
be out of direct sunlight and away from heat sources. To
assure your product performs to specifications the recom-
mended installation location temperature range is from 65
to 90°F (18 to 32°C).
CAUTION
!

Outdoor Installation

Only the 25OiM model is suitable for outdoor installations.
Building codes may require a ground fault circuit interrupter
electrical receptacle to supply electrical power to the ice
machine for outdoor applications, (see "Electrical Connec-
tion" section).
Do not install in a location where the unit will be exposed
to direct sun exposure as this may result in unsatisfactory
performance.
Winterizing your Outdoor Ice Maker
In colder climates the ice maker will need to be winter-
ized. The water fill valve needs to be disconnected from
the water supply line. The water fill line from the bottom of
the water fill valve will also need to be disconnected and
drained.
With the fill valve disconnected and the fill line drained,
leave the ice maker running and allow the unit to dump one
last time to remove any ice from the trays.
If the unit is to be sitting for a prolonged period of time not
running, it is advisable to dry out the tray with paper towels.
Cabinet Clearance
Ventilation is required from the bottom front section of the
unit. Keep this area open and clear of any obstructions.
Adjacent cabinets and counter top can be installed around
the unit as long as the front grille remains unobstructed.

INSTALLING YOUR ICE MACHINE

4
CAUTION
!
Front Grille
Do not obstruct the front grille. The openings within the
front grille allow air to flow through the condenser heat ex-
changer. Restrictions to this air flow will result in increased
energy usage and loss of cooling capacity. For this reason
it is important this area to not be obstructed and the grille
openings kept clean. AGA MARVEL does not recommend
the use of custom made grilles as air flow may be restricted
because of inadequate openings. (See Figure 2).
Front

Leveling Legs

Figure 2
Front Grille,
keep this area
open.
Rear
Leveling
legs