OPERATION
• The hand dryer is supplied in the "ON" position.
• The device starts automatically after a few seconds (an internal test
for correct operation is taking place).
• Insert hands completely in the opening: starts automatically when hands are
detected by sensors (fig. A).
• The heating resistor is activated at ambient temperatures <25ºC. During
drying, the diffuser (fig. A) lights up in red if the resistance is active
and in blue if it is inactive.
• During operation a countdown of seconds, represented with bars, takes place
(fig. B). The red LED lights up.
• Stops automatically when hands are removed or after 12 seconds of drying.
Stops automatically if use continues for more than 30 seconds.
The blue LED lights up.
• The hand dryer is equipped with a reservoir to collect water.
TECHNICAL FEATURES
• Low energy consumption: 1,050W in mode without heating,
1,550W with heating.
• 230V~ / 50Hz.
• Air flow rate: 61 l/s. Air speed: 540 km/h.
• Acoustic level: 66 dBA.
• Class II, IP21.
• The sensitivity of sensors can be adjusted by setting the potentiometers
situated inside the hand dryer (fig. C).
INSTALLATION AND ELECTRICAL CONNECTION
The electrical connection should be carried out before fixing the hand dryer
to the wall.
• Switch off the product before carrying out any work.
• Remove the cover plate (fig. D), pass the mains power supply cable,
for example type H05RN - F2 x Ø 1.5mm (not supplied), through the hole
(fig. E) and screw it to the connection lead.
• Fix the cable holding piece to prevent it coming off as a result of pulling.
• The installation must comply with the current regulations and guidelines
of the country of installation.
• Recommended installation height (distance between floor and top of device):
A - 95cm for adults, 85cm for children and disabled people (fig. F
• Drill the wall before installing the support plate. Fix the plate to the wall
with the screws and rawl plugs provided (fig. F
screws and rawl plugs depending on the wall type.
• Attach the hand dryer to the wall plate (fig. G), remove the filter then fix
the 2 screws to the lower part and put the filter back.
• To put in ON/OFF mode, remove the screws a from both sides of the hand
dryer and reposition the cover (fig. H).
• Activate the product by connecting it to the electrical supply.
REMINDER
• Our products must be installed by professional installers in accordance
with current regulations and recommendations in your country, and the
specifications of the engineer.
• Avoid splashes inside the mechanism of the hand dryer.
• Do not shake the hand dryer.
• In the event of disfunction, immediately turn the hand dryer off and contact
our After Sales Support Team.
• Do not install the hand dryer outside or on a flammable surface.
SETTINGS
If the sensors appear to be having problems detecting the hands,
it is possible to adjust the sensors:
- remove the cover and screws from both sides of the hand dryer a (fig. H);
- slide the cover upwards to remove it (fig. H);
- adjust the sensors' sensitivity using the potentiometers and by turning
clockwise or anti-clockwise to reach the desired setting (fig. C).
EN
).
1
). If necessary use different
2
MAINTENANCE (FIG. B)
The hand dryer is equipped with alarms to notify when maintenance is required:
+1: the HEPA filter is full. It must be changed (cf. MAINTENANCE &
CLEANING section).
+3: the carbon from the motor is at the end of its life and must be changed.
Once the maintenance has been carried out, restart the motor counter to
know when to change the carbon again. Now press the restart button
and activate the ON switch at the same time (fig. H).
Continue pressing for a few seconds until the 1
Release the button : the reset is complete and all the bars are lit up
continuously.
The reservoir to collect the water is almost full. It must be emptied and
cleaned (cf. MAINTENANCE & CLEANING section).
The DELABIE logo is flashing: for more than 30 seconds an object has prevented
the hand dryer from stopping. The hand dryer stops automatically.
Once the object is removed, the operation will restart automatically.
The diffuser (fig. A) lights up in red but the hand dryer is not blowing out
warm air: it means that the heating resistor is not working. Wait a few minutes
for the hand dryer to cool down. If this persists, contact Technical Support.
MAINTENANCE & CLEANING
The hand dryer is equipped with alarms to notify when maintenance is required:
• Clean regularly using a soft damp cloth. Never use abrasives, scouring powder
or any other chlorine, acid or alcohol-based products.
• Clean the infrared sensors' glass regularly.
• Ensure the channel is clean and not obstructed by any substances or impurities.
• Keep the air intake area clear.
• Clean the opening for hands regularly and completely.
• Empty and clean the reservoir for collecting the water. Turn the locking screw
(fig. I) and remove the reservoir from beneath. Remove the cover. Empty
and clean the reservoir. Replace the cover on the reservoir and place the
whole assembly in its original location. Turn the locking screw to lock the
assembly in place.
Changing the HEPA filter
Turn the locking screw (fig. I) and remove the filter housing from beneath.
Remove the filter and replace it with a new one. Replace the filter housing in its
original location. Turn the locking screw to lock the assembly in place.
Product conforms to current European Directives.
Product compliant for sale in Great Britain.
Compliant product for marketing in Morocco.
After Sales Care Support:
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
The installation guide is available on: www.delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
The installation guide is available on: www.delabie.com
EN
bar (fig. B) lights up.
st