Screw
Figure 7
2. Continuous Ventilation: For two speed fans wired for continuous ventilation with the
recommended AKS3 switch (not included). Properly ground the switch. Connect
the Black (Hot) wire from the supply to both the Blue wire of the fan and a black wire
run to the common terminal of the wall switch. Run 3 wires from the wall switch (not
included) to the fan. Connect the Yellow wire from the fan to the top terminal of the
AKS3 switch. This is the light control. Connect the Purple wire from the fan to the
middle terminal of the AKS3 switch. This is the night light control. Connect the black
wire from the fan to the bottom terminal of the AKS3 switch. This is the fan control
and closing the switch will change from normal to high speed (Figure 8).
Supply from
house
Ground
(Green or
Bare)
Figure 8
3. Intermittent Ventilation: For two speed fans wired for intermittent ventilation with
the recommended AKS4 switch (not included). Properly ground the switches.
Run a wire from the Blue wire in the fan to the Common terminal of one of the
switches. Connect the Black wire from the power source to the top terminal of
the switch. This will turn the fan on and off. Run a wire from the Black wire in the
fan to the bottom terminal of the same switch. This is the fan speed control and
closing the switch will change from normal to high speed. On the second switch
run a Black (Hot) wire from the supply to the common terminal of the switch. On
the same switch run a wire from the Yellow wire in the fan to the top terminal of
the switch. This is the light control. Run a wire from the Purple wire in the fan to
the bottom terminal of the switch you just connected the yellow wire to. This is the
night light control (Figure 9).
Supply from
house
Ground
(Green or
Bare)
Figure 9
A210952014 New 10-10
Wire Compartment
Hot (Black)
Neutral (White)
Blue
Black
Yellow
Purple
Black
Hot (Black)
Neutral (White)
Yellow
Black
Switch
Switch
Blue
Black
NOTE: The fan's receptacle wires might need to be pulled outside compartment for
connection. Only pull the three loose wires outside of compartment. Additional wires
Cover
will be present.
4. Carefully tuck wires back inside wire compartment and replace wire compartment
cover securing with the screw that was removed earlier.
SECTION 6
Completing the Installation
1. If the fan's blower assembly was removed during the wiring process, reinstall the
blower by reversing the directions in Step 1b in Section 5 Wiring.
2. Plug the fan's 5 pin quick connect motor cord into the receptacle on the side of
the wiring compartment cover and the light's 4 pin quick connect into the recep-
tacle on the top of the wiring compartment cover. These cords will only fit one
way into the receptacles (Figure 10).
Figure 10
3. Install the included 26 watt fluorescent lamp into the lamp holder by lining up the
pins on the lamp base to the socket of the lamp holder and pressing towards the
lamp holder until the lamp snaps into place and is firmly seated in the lamp holder.
Install a 4 watt maximum type C7 (candelabra base) night light (not included) into
the side lamp holder (Figure 11).
Lamp
Figure 11
4. Install the grill by squeezing the two ends of the springs together and installing them
up into the slots on the fan's housing. Push the grill up into position (Figure 12).
Figure 12
5. Restore power and test your installation.
www.airkinglimited.com
Night Light
Socket
Pin
Lamp Holder
3 of 12