ECODESIGN: DIRECTIVE 2009/125/EC ErP REGULATION 2016/2281/EC
INFORMATIONS POUR GENERATEURS D'AIR CHAUD SERIES X, XO, XE, XEO, XR, XP certifiés GAR 2016/426
ECODESIGN DIRECTIVE 2009/125/(EC ErP REGULATION 2016/2281/EC
INFORMATION REQUIREMENTS FOR WARM AIR HEATERS SERIES L, LO, LE, LEO, LP, LR certified GAR 2016/426 (EU)
Warm air heater type corresponding variation as abo
Heat output load range
Heat output control
B1 warm air heater
C2 warm air heater
C4 warm air heater
Type of fuel
Rated heating capacity
Minimum capacity
Electric power consumption at rated heating capacity
Electric power consumption at minimal capacity
Electric power consumption in standby mode
Useful efficiency at rated heating capacity, by Hs
Useful efficiency at minimum capacity, by Hs
Envelope loss factor for W.A.H. not- installed in heated area
Envelope loss factor for W.A.H. installed in heated area
Ignition burner power consumption
Emission of nitrogen oxides by Hs (GCV) with G20 (a)
Emission efficiency
Seasonal space heating energy efficiency for W.A.H. not-installed in heated area
Seasonal space heating energy efficiency for W.A.H. installed in heated area
NOTE: W.A.H.= warm air heater.
a) NOx values are calculated according to EN17082:2019 par 6.8 and are valid with gas blast burners Low Nox certified ERP 2° STEP ≤ 70 mg/kWh or complying with Low Nox emission ≤ 70 mg/kWh.
symbol
unit
L30
100-50%
100-30%
2 stage
modulating
yes/no
no
no
yes/no
no
no
yes/no
no
no
gas/liquid
gas
gas
P rated,h
kW
30,6
30,6
P min
kW
18,4
10,2
el max
Kw
0,280
0,280
el min
Kw
0,252
0,252
el sb
Kw
0,010
0,010
η nom
%
84,6
84,6
η pl
%
89,8
91,8
Fenv
%
1
1
Fenv
%
0
0
Pign
Kw
0
0
NOx
mg/kWh 63
63
ηs, flow
%
0,930
0,953
78,8
85,3
ηs,h
%
ηs,h
%
79,8
86,2
L60
L80
100-50%
100-30%
100-50%
100-30%
2 stage
2 stage
modulating
modulating
no
no
no
no
no
no
no
no
no
no
no
no
gas
gas
gas
gas
56,0
56,0
94,7
94,7
26,7
19,6
47,7
33,4
0,280
0,280
0,430
0,430
0,252
0,252
0,387
0,387
0,010
0,010
0,010
0,010
86,9
86,9
86,5
86,5
93,4
95,2
89,4
97,0
1
1
1
1
0
0
0
0
0
0
0
0
69,2
69,2
62
62
0,943
0,954
0,931
0,946
85,8
90,3
79,3
88,9
86,8
91,3
80,3
89,8
L100
L150
100-50%
100-30%
100-50%
100-30%
2 stage
2 stage
modulating
modulating
no
no
no
no
no
no
no
no
no
no
no
no
gas
gas
gas
gas
110,2
110,2
172,4
172,4
53,8
33,4
82,3
54,8
0,430
0,430
0,460
0,460
0,387
0,387
0,414
0,414
0,010
0,010
0,010
0,010
85,7
85,7
86,7
86,7
88,1
97,0
90,4
93,1
1
1
1
1
0
0
0
0
0
0
0
0
57,6
57,6
67,4
67,4
0,935
0,953
0,930
0,946
78,7
89,8
80,2
86,1
79,6
90,8
81,1
87,0
P a g .
L175
100-50%
100-30%
2 stage
modulating
no
no
no
no
no
no
gas
gas
198,3
198,3
86,4
54,8
0,460
0,460
0,414
0,414
0,010
0,010
87,9
87,9
91,5
93,1
1
1
0
0
0
0
67,8
67,8
0,938
0,954
82,2
87,0
83,1
88,0
20 | 57