display shows [000000], input sample weight. Press
4. In this function, press
FUNCTION OF ANIMAL SCALE F2.1 =
Operation method
In normal weighing state, place the animal on the weighing platform and its weight must be ≥threshold value set in F2.2. Press
instrument will collect data sampling. After sampling, the average value of sampling data will be locked, showing A X.XXX. Press
or
to quit the interface.
VII PROMPT MESSAGE OF INSTRUMENT
The instrument has extremely high stability and reliability, thus is not easy to
please make clear the error first and observe whether the instrument still has error after power-on. Do not hurry to repair the scale body or instrument.
Repair the instrument according to error code of the instrument as possible.
Symbol
1
[-EEE]
[ EEE]
2
[
]
3
[
]
4
[
]
[
]
5
6
[Err 03]
7
[Err 0]
8
[Err 06]
9
[Err 07]
10
[Err 08]
11
[Err 09]
12
[LOAd]
13
[ EtUP]
14
[End
]
15
[Add-- ]
16
[-OUER-]
to display switch between quantity and weight.
6
Analysis
Unable to reset after startup
The weighed object is over full range for 9 days
The weighed object is below 0 for 5
Out of clearing range
Invalid operation
EEPROM checksum and error
The calibration input weight is too small
The weight in calibration is too light
The scale is dynamic in scale
Setting error of date and time
Error of AD initialization
In loading scale, it indicates to loading weight;
It has enters menu setting
End of point and loading point calibration
Including current display weight in accumulated value
Accumulated weight overflows
, the instrument saves setting data and quits sampling setting interface.
Remark
1. Determine it is no-load state in startup;
2. Make calibration again.
Reduce weight on weighing platform
DAYS
Press
Check whether the weighing platform has weight.
Remove weight.
Press
information occurs again, return to factory for repair.
Please calibrate the scale again if the situation does not
occur;
Attention: this place is provided with all parameters of
instruments of the factory.
Input≥10 % weight of full range
Load≥10% weight of full range
Inspect the scale body
Set according to specification of date and time
If the error occurs after restar ting, return it to the fac-
tory for repair
Load weight according to requirements
Pres [print] to continue setting.
Clear accumulated weight in time.
have error in general situation. Once an error occurs,
to reset
reprint factory value. Start up again. If the
,
to print; press